English
Language : 

EMI4182 Datasheet, PDF (6/10 Pages) ON Semiconductor – Common Mode Filter with ESD Protection
EMI4182
Transmission Line Pulse (TLP) Measurements
Transmission Line Pulse (TLP) provides current versus voltage (I-V) curves in which each data point is obtained from a
100 ns long rectangular pulse from a charged transmission line. A simplified schematic of a typical TLP system is shown in
Figure 11. TLP I-V curves of ESD protection devices accurately demonstrate the product’s ESD capability because the 10 s
of amps current levels and under 100 ns time scale match those of an ESD event. This is illustrated in Figure 12 where an 8 kV
IEC61000-4-2 current waveform is compared with TLP current pulses at 8 and 16 A. A TLP curve shows the voltage at which
the device turns on as well as how well the device clamps voltage over a range of current levels. Typical TLP I-V curves for
the EMI4182 are shown in Figure 13.
L
50 W Coax
Cable
Attenuator
SW
50 W Coax Cable
÷
10 MW
IM
VM
VC
DUT
Oscilloscope
Figure 11. Simplified Schematic of a Typical TLP System
Figure 12. Comparison Between 8 kV IEC61000−4−2 and 8 A and 16 A TLP Waveforms
Figure 13. Positive and Negative TLP Waveforms
http://onsemi.com
6