AC ELECTRICAL CHARACTERISTICS (CL = 50 pF, Control or Enable tr = tf = 6 ns, VEE = GND)
Guaranteed Limit
Symbol
Parameter
tPLH,
tPHL
Maximum Propagation Delay, Analog Input to Analog Output
(Figures 9 and 10)
tPLZ,
tPHZ
Maximum Propagation Delay, Control or Enable to Analog Output
(Figures 11 and 12)
tPZL,
tPZH
Maximum Propagation Delay, Control or Enable to Analog Output
(Figures 11 and 12)
C
Maximum Capacitance
ON/OFF Control
and Enable Inputs
Control Input = GND
Analog I/O
Feedthrough
VCC – 55 to
V
25°C v 85°C v 125°C Unit
2.0
40
50
60
ns
4.5
6
8
9
6.0
5
7
8
2.0
130
160
200
ns
4.5
40
50
60
6.0
30
40
50
2.0
140
175
250
ns
4.5
40
50
60
6.0
30
40
50
−
10
10
10
pF
−
35
35
35
−
1.0
1.0
1.0
Typical @ 25°C, VCC = 5.0 V
CPD Power Dissipation Capacitance (Per Switch) (Figure 14)*
15
pF
*Used to determine the no−load dynamic power consumption: PD = CPD VCC2f + ICC VCC.
ADDITIONAL APPLICATION CHARACTERISTICS (GND = 0 V)
Symbol
Parameter
VCC
Test Conditions
V
BW Maximum On–Channel Bandwidth fin = 1 MHz Sine Wave
2.25
or
Adjust fin Voltage to Obtain 0 dBm at VOS
4.50
Minimum Frequency Response
Increase fin Frequency Until dB Meter
6.00
(Figure 6)
Reads – 3 dB
RL = 50 W, CL = 10 pF
−
Off–Channel Feedthrough
Isolation
(Figure 7)
fin  Sine Wave
Adjust fin Voltage to Obtain 0 dBm at VIS
fin = 10 kHz, RL = 600 W, CL = 50 pF
2.25
4.50
6.00
fin = 1.0 MHz, RL = 50 W, CL = 10 pF
2.25
4.50
6.00
−
Feedthrough Noise, Control to
Switch
(Figure 8)
Vin v 1 MHz Square Wave (tr = tf = 6 ns)
2.25
Adjust RL at Setup so that IS = 0 A
4.50
RL = 600 W, CL = 50 pF 6.00
RL = 10 kW, CL = 10 pF 2.25
4.50
6.00
−
Crosstalk Between Any Two
Switches
(Figure 13)
fin  Sine Wave
Adjust fin Voltage to Obtain 0 dBm at VIS
fin = 10 kHz, RL = 600 W, CL = 50 pF
fin = 1.0 MHz, RL = 50 W, CL = 10 pF
2.25
4.50
6.00
2.25
4.50
6.00
THD
Total Harmonic Distortion
(Figure 15)
fin = 1 kHz, RL = 10 kW, CL = 50 pF
THD = THDMeasured − THDSource
VIS = 4.0 VPP sine wave
VIS = 8.0 VPP sine wave
VIS = 11.0 VPP sine wave
*Limits not tested. Determined by design and verified by qualification.
2.25
4.50
6.00
VEE
V
– 2.25
– 4.50
– 6.00
– 2.25
– 4.50
– 6.00
– 2.25
– 4.50
– 6.00
– 2.25
– 4.50
– 6.00
– 2.25
– 4.50
– 6.00
– 2.25
– 4.50
– 6.00
– 2.25
– 4.50
– 6.00
– 2.25
– 4.50
– 6.00
Limit*
25°C
150
160
160
Unit
MHz
– 50
dB
– 50
– 50
– 40
– 40
– 40
30
mVPP
65
100
60
130
200
– 70
dB
– 70
– 70
– 80
– 80
– 80
%
0.10
0.06
0.04