English
Language : 

MC10EP57_14 Datasheet, PDF (5/10 Pages) ON Semiconductor – ECL 4:1 Differential Multiplexer
MC10EP57, MC100EP57
Table 7. 10EP DC CHARACTERISTICS, NECL VCC = 0 V, VEE = −5.5 V to −3.0 V (Note 8)
−40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
IEE
VOH
Power Supply Current
Output HIGH Voltage (Note 9)
40
52
65
40
52
65
40
52
65 mA
−1135 −1010 −885 −1070 −945 −820 −1010 −885 −760 mV
VOL
VIH
VIL
VBB
VIHCMR
Output LOW Voltage (Note 9)
Input HIGH Voltage (Single−Ended)
Input LOW Voltage (Single−Ended)
Output Voltage Reference
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(Note 10)
−1935 −1810 −1685 −1870 −1745 −1620 −1810 −1685 −1560 mV
−1210
−885 −1145
−820 −1085
−760 mV
−1935
−1610 −1870
−1545 −1810
−1485 mV
−1510 −1465 −1310 −1445 −1400 −1245 −1385 −1340 −1185 mV
VEE + 2.0
0.0
VEE + 2.0
0.0
VEE + 2.0
0.0
V
IIH
Input HIGH Current
IIL
Input LOW Current
150
150
150 mA
0.5
0.5
0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
8. Input and output parameters vary 1:1 with VCC.
9. All loading with 50 W to VCC − 2.0 V.
10. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential
input signal.
Table 8. 100EP DC CHARACTERISTICS, PECL VCC = 3.3 V, VEE = 0 V (Note 11)
−40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
IEE
VOH
VOL
VIH
VIL
VBB
VIHCMR
Power Supply Current
Output HIGH Voltage (Note 12)
Output LOW Voltage (Note 12)
Input HIGH Voltage (Single−Ended)
Input LOW Voltage (Single−Ended)
Output Voltage Reference
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(Note 13)
40
52
65
40
52
65
40
52
65 mA
2155 2280 2405 2155 2280 2405 2155 2280 2405 mV
1305 1480 1605 1305 1480 1605 1305 1480 1605 mV
2075
2420 2075
2420 2075
2420 mV
1305
1675 1305
1675 1305
1675 mV
1775 1875 1975 1775 1875 1975 1775 1875 1975 mV
2.0
3.3 2.0
3.3 2.0
3.3 V
IIH
Input HIGH Current
IIL
Input LOW Current
150
150
150 mA
0.5
0.5
0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
11. Input and output parameters vary 1:1 with VCC. VEE can vary +0.3 V to −2.2 V.
12. All loading with 50 W to VCC − 2.0 V.
13. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential
input signal.
http://onsemi.com
5