English
Language : 

CAT5116LI Datasheet, PDF (5/11 Pages) ON Semiconductor – Log‐taper, 100‐tap Digital Potentiometer (POT)
CAT5116
Table 5. AC TEST CONDITIONS
VCC Range
Input Pulse Levels
Input Rise and Fall Times
Input Reference Levels
2.5 V  VCC  5.5 V
0.2 VCC to 0.7 VCC
10 ns
0.5 VCC
Table 6. AC OPERATING CHARACTERISTICS (VCC = +2.5 V to +5.5 V, VH = VCC, VL = 0 V, unless otherwise specified)
Symbol
Parameter
Min
Typ (Note 7)
Max
Units
tCI
CS to INC Setup
100
−
−
ns
tDI
U/D to INC Setup
50
−
−
ns
tID
U/D to INC Hold
100
−
−
ns
tIL
INC LOW Period
250
−
−
ns
tIH
INC HIGH Period
250
−
−
ns
tIC
INC Inactive to CS Inactive
1
−
−
ms
tCPH1
CS Deselect Time (NO STORE)
100
−
−
ns
tCPH2
CS Deselect Time (STORE)
10
−
−
ms
tIW
INC to VOUT Change
−
1
5
ms
tCYC
INC Cycle Time
1
−
−
ms
tR, tF (Note 8) INC Input Rise and Fall Time
−
−
500
ms
tPU (Note 8) Power-up to Wiper Stable
–
–
1
ms
tWR
Store Cycle
–
5
10
ms
7. Typical values are for TA = 25C and nominal supply voltage.
8. This parameter is periodically sampled and not 100% tested.
9. MI in the A.C. Timing diagram refers to the minimum incremental change in the W output due to a change in the wiper position.
CS
tCYC
tCI
tIL
tIH
tIC
INC
tDI tID
U/D
(store)
tCPH
90% 90%
10%
tF
tR
tIW
RW
Figure 5. A.C. Timing
MI(3)
http://onsemi.com
5