CAT5270
Table 5. D.C. OPERATING CHARACTERISTICS (VCC = +2.5 V to +5.5 V, unless otherwise specified.)
Symbol
Parameter
Test Conditions
Min
ICC
ISB
ILI
ILO
VIL
VIH
VOL1
Power Supply Current
Standby Current (VCC = 5.0 V)
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage (VCC = 2.5 V)
fSCL = 400 kHz, SDA = Open
VCC = 5.5 V, Inputs = GND
VIN = GND or VCC, SDA = Open
VIN = GND to VCC
VOUT = GND to VCC
IOL = 3 mA
−1
VCC x 0.7
Max
1
5
10
10
VCC x 0.3
VCC + 1.0
0.4
Units
mA
mA
mA
mA
V
V
V
Table 6. CAPACITANCE (TA = 25°C, f = 1.0 MHz, VCC = 5 V)
Symbol
Test
CI/O (Note 8)
CIN (Note 8)
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, A3, SCL, WP)
Conditions
VI/O = 0 V
VIN = 0 V
Max
Units
8
pF
6
pF
Table 7. A.C. CHARACTERISTICS
Symbol
fSCL
TI (Note 8)
tAA
tBUF (Note 8)
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR (Note 8)
tF (Note 8)
tSU:STO
tDH
Parameter
Clock Frequency
Noise Suppression Time Constant at SCL, SDA Inputs
SLC Low to SDA Data Out and ACK Out
Time the bus must be free before a new transmission can start
Start Condition Hold Time
Clock Low Period
Clock High Period
Start Condition Setup Time (for a Repeated Start Condition)
Data in Hold Time
Data in Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
2.5 V – 5.5 V
Min
Max
400
200
1
1.2
0.6
1.2
0.6
0.6
0
50
0.3
300
0.6
100
Units
kHz
ns
ms
ms
ms
ms
ms
ms
ns
ns
ms
ns
ms
ns
Table 8. POWER UP TIMING (Notes 8 and 9)
Symbol
tPUR
tPUW
Power−up to Read Operation
Power−up to Write Operation
Parameter
Max
Units
1
ms
1
ms
Table 9. WIPER TIMING
Symbol
Parameter
Max
tWRPO
Wiper Response Time After Power Supply Stable
10
tWRL
Wiper Response Time After Instruction Issued
10
8. This parameter is tested initially and after a design or process change that affects the parameter.
9. tPUR and tPUW are delays required from the time VCC is stable until the specified operation can be initiated.
Units
ms
ms
http://onsemi.com
4