English
Language : 

NCP1246_15 Datasheet, PDF (34/39 Pages) ON Semiconductor – Fixed Frequency Current Mode Controller
NCP1246
PROTECTION MODES AND THE LATCH MODE RELEASES
Event
Timer Protection
Next Device Status
Overcurrent
VILIM > 0.7 V
Fault timer
Latch
Maximum on time
Fault timer
Latch
Winding short
Vsense > VCS(stop)
Low supply
VCC < VCC(off)
External OTP, OVP
High supply
VCC > VCC(ovp)
Brown−out
VHV < VHV(stop)
Internal TSD
Off mode
VFB < VOFF
Immediate reaction
Latch
10 ms timer
Latch
55 ms (35 ms at 100 kHz)
10 ms timer
HV timer
10 ms timer
150 ms timer
Latch
Latch
Device stops
Device stops, HV start−up
current source stops
Device stops and internal
VCC is turned off
Release to Normal Operation Mode
Autorecovery – B version
Brown−out
VCC < VCC(reset)
Autorecovery – B version
Brown−out
VCC < VCC(reset)
Autorecovery – B version
Brown−out
VCC < VCC(reset)
Autorecovery – B version
Brown−out
VCC < VCC(reset)
Brown−out
VCC < VCC(reset)
Brown−out
VCC < VCC(reset)
(VHV > VHV(start))&( VCC > VCC(on))
(VHV > VHV(start)) & ( VCC > VCC(on)) &
TSDb
(VHV > VHV(start)) & ( VCC > VCC(on)) &
( VFB > VON)
www.onsemi.com
34