MC74LCX07 Datasheet, PDF (3/6 Pages) ON Semiconductor – Low-Voltage CMOS Hex Buffer with Open Drain Outputs | |||
|
◁ |
MC74LCX07
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
VCC
Supply Voltage
Operating
Data Retention Only
VI
VO
IOH
IOL
TA
Dt/DV
Input Voltage
Output Voltage
(HIGH or LOW State)
HIGH Level Output Current
LOW Level Output Current
Operating FreeâAir Temperature
VCC= 3.0 Vâ3.6 V
VCC= 2.7 Vâ3.0 V
VCC= 2.3 Vâ2.7 V
VCC= 3.0 Vâ3.6 V
VCC= 2.7 Vâ3.0 V
VCC= 2.3 Vâ2.7 V
Input Transition Rise or Fall Rate, VIN from 0.8 V to 2.0 V, VCC = 3.0 V
Min
Typ
Max
2.0
2.3 to 3.3
5.5
1.5
5.5
0
5.5
0
5.5
â24
â12
â8
+24
+12
+8
â40
+85
0
10
Unit
V
V
V
mA
mA
°C
ns/V
DC ELECTRICAL CHARACTERISTICS
Symbol
Characteristic
VIH
HIGH Level Input Voltage (Note 2)
VIL
LOW Level Input Voltage (Note 2)
VOL
LOW Level Output Voltage
Condition
2.3 V v VCC v 2.7 V
2.7 V v VCC v 3.6 V
2.3 V v VCC v 2.7 V
2.7 V v VCC v 3.6 V
2.3 V v VCC v 3.6 V; IOL = 100 mA
VCC = 2.3 V; IOL= 8 mA
TA = â40°C to +85°C
Min
Max
Unit
1.7
V
2.0
0.7
V
0.8
0.2
V
0.3
VCC = 2.7 V; IOL= 12 mA
0.4
II
Maximum Input Leakage Current
IOFF
PowerâOff Leakage Current
ICC
Maximum Quiescent Supply Current
VCC = 3.0 V; IOL = 16 mA
VCC = 3.0 V; IOL = 24 mA
2.3 V v VCC v 3.6 V, 0 V v VI v 5.5 V
VCC = 0V, VO or VI = 5.5V
2.3 V v VCC v 3.6 V, VI= VCC or GND
2.3 V v VCC v3.6 V, 3.6 V vVI v5.5 V
0.4
0.55
$5
mA
10
mA
10
mA
$10
DICC
Increase in ICC per Input
2.3 V v VCC v
4.5 V v VCC v
2. These values of VI are used to test DC electrical characteristics only.
3.6 V
5.5 V
500
mA
1.0
mA
AC ELECTRICAL CHARACTERISTICS
Symbol
tPLZ
tPZL
Parameter
Propagation Delay
Input to Output
Limits
VCC = 3.3 V $ 0.3 V
CL= 50 pF
Min
Max
TA= â405C to +855C
VCC= 2.7 V
CL= 50 pF
Min
Max
VCC = 2.5 V $ 0.2 V
CL= 30 pF
Min
Max
Unit
0.5
3.0
0.8
3.7
0.8
3.8
ns
0.5
3.0
0.8
3.7
0.8
3.8
ns
DYNAMIC SWITCHING CHARACTERISTICS
Symbol
Characteristic
Condition
TA = +25°C
Min Typ Max Unit
VOLP
Dynamic LOW Peak Voltage (Note 3)
VCC = 3.3 V, CL = 50 pF, VIH = 3.3 V, VIL = 0 V
0.9
V
VCC = 2.5 V, CL = 30 pF, VIH =2.5 V, VIL = 0 V
0.7
VOLV
Dynamic LOW Valley Voltage (Note 3) VCC = 3.3 V, CL = 50 pF, VIH = 3.3 V, VIL = 0 V
â0.8
V
VCC = 2.5 V, CL = 30 pF, VIH = 2.5 V, VIL = 0 V
â0.6
3. Number of outputs defined as ânâ. Measured with ânâ1â outputs switching from HIGHâtoâLOW or LOWâtoâHIGH. The remaining output is
measured in the LOW state.
http://onsemi.com