English
Language : 

MC74HC4538A_16 Datasheet, PDF (3/14 Pages) ON Semiconductor – Dual Precision Monostable Multivibrator
MC74HC4538A
MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
VCC DC Supply Voltage
VI
DC Input Voltage
VO
DC Output Voltage
IIK
DC Input Diode Current
IOK
IO
ICC
IGND
TSTG
TL
TJ
qJA
DC Output Diode Current
DC Output Sink Current
DC Supply Current per Supply Pin
DC Ground Current per Ground Pin
Storage Temperature Range
Lead temperature, 1 mm from Case for 10 Seconds
Junction temperature under Bias
Thermal resistance
(Note 1)
A, B, Reset
CX, RX
SOIC
TSSOP
−0.5 to +7.0
−0.5 ≤ VI ≤ VCC + 0.5
−0.5 ≤ VO ≤ VCC + 0.5
±20
±30
±25
±25
±100
±100
−65 to +150
260
+150
112
148
V
V
V
mA
mA
mA
mA
mA
_C
_C
_C
_C/W
PD
Power Dissipation in Still Air at 85_C
SOIC
500
mW
TSSOP
450
MSL Moisture Sensitivity
Level 1
FR
VESD
Flammability Rating
ESD Withstand Voltage
Oxygen Index: 30% − 35%
UL−94−VO (0.125 in)
Human Body Model (Note 2)
> 2000
V
Machine Model (Note 3)
> 100
Charged Device Model (Note 4)
> 500
ILatchup Latchup Performance
Above VCC and Below GND at 85_C (Note 5)
±300
mA
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. IO absolute maximum rating must be observed.
2. Tested to EIA/JESD22−A114−A.
3. Tested to EIA/JESD22−A115−A.
4. Tested to JESD22−C101−A.
5. Tested to EIA/JESD78.
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
Max
Unit
VCC
Vin, Vout
TA
tr, tf
DC Supply Voltage (Referenced to GND)
DC Input Voltage, Output Voltage (Referenced to GND)
Operating Temperature, All Package Types
Input Rise and Fall Time
(Figure 6)
A or B (Figure 4)
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
2.0
6.0
V
0
VCC
V
–55
+125
_C
0
1000
ns
0
500
0
400
−
No Limit
Rx
External Timing Resistor
VCC < 4.5 V
VCC ≥ 4.5 V
1.0
†
kW
2.0
†
Cx
External Timing Capacitor
0
†
mF
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
†The maximum allowable values of Rx and Cx are a function of the leakage of capacitor Cx, the leakage of the HC4538A, and leakage due to board layout
and surface resistance. For most applications, Cx/Rx should be limited to a maximum value of 10 mF/1.0 MW. Values of Cx > 1.0 mF may cause a
problem during power down (see Power Down Considerations). Susceptibility to externally induced noise signals may occur for Rx > 1.0 MW.
6. Unused inputs may not be left open. All inputs must be tied to a high−logic voltage level or a low−logic input voltage level.
http://onsemi.com
3