Table 3. PECL INPUT DC CHARACTERISTICS (VCC = 5.0 V; LVCC = 3.3 V; GND = 0 V Note 1))
−40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
IVCC
VIH
VIL
PECL VBB
VIHCMR
IIH
IIL
PECL Power Supply Current
Input HIGH Voltage (Single-Ended)
Input LOW Voltage (Single-Ended)
Output Voltage Reference
Input HIGH Voltage Common Mode
Range (DIfferential) (Note 2)
Vpp < 500 mV
Vpp ≥ 500 mV
Input HIGH Current
Input LOW Current
D
D
3835
3190
3.62
1.3
1.5
0.5
−600
12
4120
3515
3.74
3835
3190
3.62
4.8 1.2
4.8 1.4
150
0.5
−600
12
4120
3525
3.74
3835
3190
3.62
4.8 1.2
4.8 1.4
150
0.5
−600
12 mA
4120 mV
3525 mV
3.74 V
V
4.8
4.8
150 mA
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input parameters vary 1:1 with VCC. VCC can vary 4.5 V to 5.5 V.
2. VIHCMR min varies 1:1 with GND. VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential
input signal. Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies between VPPmin
and 1.0 V.
Table 4. LVPECL OUTPUT DC CHARACTERISTICS (VCC = 5.0 V; LVCC = 3.3 V; GND = 0 V (Note 1))
−40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
ILVCC
VOH
VOL
LVPECL Power Supply Current
Output HIGH Voltage (Note 2)
Output LOW Voltage (Note 2)
20
20
21 mA
2215 2295 2420 2275 2345 2420 2275 2345 2420 mV
1470 1605 1745 1490 1595 1680 1490 1595 1680 mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Output parameters vary 1:1 with LVCC. VCC can vary 3.0 V to 3.8 V.
2. Outputs are terminated through a 50 W resistor to LVCC − 2.0 V.
www.onsemi.com