English
Language : 

CM1420 Datasheet, PDF (3/12 Pages) California Micro Devices Corp – LCD EMI Filter Array with ESD Protection
CM1420, CM1422
SPECIFICATIONS
Table 2. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Units
Storage Temperature Range
−65 to +150
°C
DC Power per Resistor
100
mW
DC Package Power Rating
500
mW
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 3. STANDARD OPERATING CONDITIONS
Parameter
Operating Temperature Range
Rating
−40 to +85
Units
°C
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Note 1)
Symbol
Parameter
Conditions
Min Typ Max Units
R
Resistance
80 100 120
W
C
Capacitance
At 2.5 V DC, 1 MHz,
30 mV AC
12
15
18
pF
VDIODE
ILEAK
VSIG
Diode Standoff Voltage
Diode Leakage Current (reverse bias)
Signal Clamp Voltage
Positive Clamp
Negative Clamp
IDIODE = 10 mA
VDIODE = 3.3 V
ILOAD = 10 mA
(Note 3)
6.0
V
100 200
nA
V
5.6 6.8 9.0
−1.5 −0.8 −0.4
VESD
In−system ESD Withstand Voltage
(Note 2)
a) Human Body Model, MIL−STD−883, Method 3015
b) Contact Discharge per IEC 61000−4−2 Level 4
kV
±30
±15
RDYN
Dynamic Resistance
Positive
Negative
W
2.30
0.90
fC
Cut−off Frequency
ZSOURCE = 50 W, ZLOAD = 50 W
R = 100 W, C = 15 pF
MHz
120
1. TA = 25 °C unless otherwise specified.
2. ESD applied to input and output pins with respect to GND, one at a time.
3. Clamping voltage is measured at the opposite side of the EMI filter to the ESD pin. For example, if ESD is applied to Pin A1, then clamping
voltage is measured at Pin C1.
http://onsemi.com
3