CAT3200ES6-5 Datasheet, PDF (3/12 Pages) ON Semiconductor – Low Noise Regulated Charge Pump DC-DC Converter | |||
|
◁ |
CAT3200, CAT3200â5
Table 3. RECOMMENDED OPERATING CONDITIONS
Parameters
VIN
CIN, COUT, CFLY
ILOAD
Ambient Temperature Range
Ratings
2.7 to 4.5
1
0 to 100
â40 to +85
Units
V
mF
mA
°C
Table 4. ELECTRICAL SPECIFICATIONS
(Recommended operating conditions unless otherwise specified. CIN, COUT, CFLY are 1 mF ceramic capacitors and VIN is set to 3.6 V.)
Symbol
Parameter
Conditions
Min
Typ
Max
Units
VOUT
VLINE
VLOAD
FOSC
VR
Regulated Output
Line Regulation
Load Regulation
Switching Frequency
Output Ripple Voltage
ILOAD ⤠40 mA, VIN ⥠2.7 V
ILOAD ⤠100 mA, VIN ⥠3.1 V
4.8
5.0
5.2
V
3.1 V ⤠VIN ⤠4.5 V, ILOAD = 50 mA
6
mV
ILOAD = 10 mA to 100 mA, VIN = 3.6 V
20
mV
1.3
2.0
2.6
MHz
ILOAD = 100 mA
CAT3200â5 Only
30
mVpâp
h
Efficiency
ILOAD = 50 mA, VIN = 3 V, CAT3200â5
80
%
IGND
Ground Current
ILOAD = 0 mA, SHDN = VIN
1.6
4
mA
ISHDN
Shutdown Input Current
ILOAD = 0 mA, SHDN = 0 V
1
mA
VFB
FB Voltage
CAT3200 Only
1.22 1.27 1.32
V
IFB
FB Input Current
CAT3200 Only
â50
50
nA
ROL
OpenâLoop Resistance
ILOAD = 100 mA, VIN = 3 V (Note 1)
10
W
TON
VOUT Turnâon time (10% to 90%)
ILOAD = 0 mA, VIN = 3 V
0.5
ms
VIHSHDN
High Detect Shutdown Threshold
0.8
1.3
V
VILSHDN
Low Detect Shutdown Threshold
0.4
V
IROUT
Reverse Leakage into OUT pin
VOUT = 5 V, Shutdown mode (Note 2)
15
30
mA
ISC
Shortâcircuit Output
VOUT = 0 V
80
mA
TSD
Thermal Shutdown
160
°C
THYST
Thermal Hysteresis
20
°C
1. ROL = (2VIN â VOUT)/IOUT
2. In the event of a controlled shutdown, the output will be isolated from the input, but will remain connected to the internal resistor feedback
network. This will cause a small level of reverse current to flow back into the device to ground.
http://onsemi.com
3
|
▷ |