English
Language : 

CAT25080LI Datasheet, PDF (3/19 Pages) ON Semiconductor – 8-Kb and 16-Kb SPI Serial CMOS EEPROM
CAT25080, CAT25160
Table 5. A.C. CHARACTERISTICS − Mature Product
(TA = −40°C to +85°C (Industrial) and TA = −40°C to +125°C (Extended)) (Notes 4, 7)
Symbol
Parameter
VCC = 1.8 V − 5.5 V
Min
Max
VCC = 2.5 V − 5.5 V
TA = −405C to +855C
Min
Max
Units
fSCK
tSU
tH
Clock Frequency
Data Setup Time
Data Hold Time
DC
5
DC
40
20
40
20
10
MHz
ns
ns
tWH
tWL
tLZ
tRI (Note 5)
tFI (Note 5)
SCK High Time
SCK Low Time
HOLD to Output Low Z
Input Rise Time
Input Fall Time
75
40
75
40
50
2
2
ns
ns
25
ns
2
ms
2
ms
tHD
HOLD Setup Time
tCD
HOLD Hold Time
tV
Output Valid from Clock Low
tHO
Output Hold Time
tDIS
Output Disable Time
0
0
10
10
75
0
0
50
ns
ns
40
ns
ns
20
ns
tHZ
tCS
tCSS
tCSH
HOLD to Output High Z
CS High Time
CS Setup Time
CS Hold Time
100
50
20
20
15
30
20
25
ns
ns
ns
ns
tCNS
CS Inactive Setup Time
20
15
tCNH
CS Inactive Hold Time
20
15
tWPS
WP Setup Time
10
10
tWPH
WP Hold Time
100
60
tWC (Note 6)
Write Cycle Time
5
4. AC Test Conditions:
Input Pulse Voltages: 0.3 VCC to 0.7 VCC
Input rise and fall times: ≤ 10 ns
Input and output reference voltages: 0.5 VCC
Output load: current source IOL max/IOH max; CL = 50 pF
5. This parameter is tested initially and after a design or process change that affects the parameter.
ns
ns
ns
ns
5
ms
6. tWC is the time from the rising edge of CS after a valid write sequence to the end of the internal write cycle.
7. All Chip Select (CS) timing parameters are defined relative to the positive clock edge (Figure 2). tCSH timing specification is valid
for die revision C and higher. The die revision C is identified by letter “C” or a dedicated marking code on top of the package. For
previous product revision (Rev. B) the tCSH is defined relative to the negative clock edge.
Table 6. POWER−UP TIMING (Notes 5, 8)
Symbol
Parameter
Max
tPUR
Power−up to Read Operation
1
tPUW
Power−up to Write Operation
1
8. tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated.
Units
ms
ms
http://onsemi.com
3