MC79M00 Series
MAXIMUM RATINGS (TA = 25°C, unless otherwise noted.)
Rating
Symbol
Value
Unit
Input Voltage
Power Dissipation
VI
−35
Vdc
Case 221A (TO−220−3)
TA = 25°C
Thermal Resistance, Junction−to−Ambient
Thermal Resistance, Junction−to−Case
Case 369C (DPAK−3)
PD
Internally Limited W
qJA
65
°C/W
qJC
5.0
°C/W
TA = 25°C
PD
Internally Limited W
Thermal Resistance, Junction−to−Ambient
qJA
92
°C/W
Thermal Resistance, Junction−to−Case
qJC
6.0
°C/W
Storage Junction Temperature
Tstg
−65 to +150
°C
Operating Junction Temperature Range
TJ
−40 to +150
°C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
*This device series contains ESD protection and exceeds the following tests:
Human Body Model 2000 V per MIL_STD_883, Method 3015
Machine Model Method 200 V
MC79M05B, C
ELECTRICAL CHARACTERISTICS (VI = −10 V, IO = 350 mA, Tlow to Thigh (Note 2), unless otherwise noted.)
Characteristic
Symbol
Min
Typ
Max Unit
Output Voltage (TJ = 25°C)
Line Regulation, TJ = 25°C (Note 1)
−7.0 Vdc ≥ VI ≥ −25 Vdc
−8.0 Vdc ≥ VI ≥ −18 Vdc
VO
−4.8
−5.0
−5.2
Vdc
Regline
mV
−
7.0
50
−
2.0
30
Load Regulation, TJ = 25°C (Note 1)
5.0 mA ≤ IO ≤ 500 mA
Regload
−
mV
30
100
Output Voltage
−7.0 Vdc ≥ VI ≥ −25 Vdc, 5.0 mA ≤ IO ≤ 350 mA
VO
Vdc
−4.75
−
−5.25
Input Bias Current (TJ = 25°C)
Input Bias Current Change
−8.0 Vdc ≥ VI ≥ −25 Vdc, IO = 350 mA
5.0 mA ≤ IO ≤ 350 mA, VI = −10 V
IIB
−
4.3
8.0
mA
DIIB
mA
−
−
0.4
−
−
0.4
Output Noise Voltage, TA = 25°C, 10 Hz ≤ f ≤ 100 kHz
Ripple Rejection (f = 120 Hz)
Vn
−
40
−
mV
RR
54
66
−
dB
Dropout Voltage
IO = 500 mA, TJ = 25°C
VI−VO
Vdc
−
1.1
−
Average Temperature Coefficient of Output Voltage
IO = 5.0 mA, 0°C ≤ TJ ≤ 125°C
DVO/DT
mV/°C
−
0.2
−
1. Load and line regulation are specified at constant temperature. Change in VO due to heating effects must be taken into account separately.
Pulse testing with low duty cycle is used.
2. B = Tlow to Thigh, −40°C < TJ < 125°C C = Tlow to Thigh, 0°C < TJ < 125°C.