MC79M00 Datasheet, PDF (2/8 Pages) Motorola, Inc – THREE-TERMINAL NEGATIVE FIXED VOLTAGE REGULATORS | |||
|
◁ |
MC79M00 Series
MAXIMUM RATINGS (TA = 25°C, unless otherwise noted.)
Rating
Symbol
Value
Unit
Input Voltage
Power Dissipation
VI
â35
Vdc
Case 221A (TOâ220â3)
TA = 25°C
Thermal Resistance, JunctionâtoâAmbient
Thermal Resistance, JunctionâtoâCase
Case 369C (DPAKâ3)
PD
Internally Limited W
qJA
65
°C/W
qJC
5.0
°C/W
TA = 25°C
PD
Internally Limited W
Thermal Resistance, JunctionâtoâAmbient
qJA
92
°C/W
Thermal Resistance, JunctionâtoâCase
qJC
6.0
°C/W
Storage Junction Temperature
Tstg
â65 to +150
°C
Operating Junction Temperature Range
TJ
â40 to +150
°C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
*This device series contains ESD protection and exceeds the following tests:
Human Body Model 2000 V per MIL_STD_883, Method 3015
Machine Model Method 200 V
MC79M05B, C
ELECTRICAL CHARACTERISTICS (VI = â10 V, IO = 350 mA, Tlow to Thigh (Note 2), unless otherwise noted.)
Characteristic
Symbol
Min
Typ
Max Unit
Output Voltage (TJ = 25°C)
Line Regulation, TJ = 25°C (Note 1)
â7.0 Vdc ⥠VI ⥠â25 Vdc
â8.0 Vdc ⥠VI ⥠â18 Vdc
VO
â4.8
â5.0
â5.2
Vdc
Regline
mV
â
7.0
50
â
2.0
30
Load Regulation, TJ = 25°C (Note 1)
5.0 mA ⤠IO ⤠500 mA
Regload
â
mV
30
100
Output Voltage
â7.0 Vdc ⥠VI ⥠â25 Vdc, 5.0 mA ⤠IO ⤠350 mA
VO
Vdc
â4.75
â
â5.25
Input Bias Current (TJ = 25°C)
Input Bias Current Change
â8.0 Vdc ⥠VI ⥠â25 Vdc, IO = 350 mA
5.0 mA ⤠IO ⤠350 mA, VI = â10 V
IIB
â
4.3
8.0
mA
DIIB
mA
â
â
0.4
â
â
0.4
Output Noise Voltage, TA = 25°C, 10 Hz ⤠f ⤠100 kHz
Ripple Rejection (f = 120 Hz)
Vn
â
40
â
mV
RR
54
66
â
dB
Dropout Voltage
IO = 500 mA, TJ = 25°C
VIâVO
Vdc
â
1.1
â
Average Temperature Coefficient of Output Voltage
IO = 5.0 mA, 0°C ⤠TJ ⤠125°C
DVO/DT
mV/°C
â
0.2
â
1. Load and line regulation are specified at constant temperature. Change in VO due to heating effects must be taken into account separately.
Pulse testing with low duty cycle is used.
2. B = Tlow to Thigh, â40°C < TJ < 125°C C = Tlow to Thigh, 0°C < TJ < 125°C.
http://onsemi.com
2
|
▷ |