CAT5112 Datasheet, PDF (2/11 Pages) Catalyst Semiconductor – 32-Tap Digitally Programmable Potentiometer (DPP™)
CAT5112
PIN CONFIGURATION
PDIP 8-Lead (L)
SOIC 8 Lead (V)
MSOP 8 Lead (Z)
I¯N¯C¯ 1
8 VCC
U/D¯ 2 CAT 7 C¯¯S
RH 3
6 RL
GND 4
5 RWB
TSSOP 8 Lead (Y)
C¯¯S 1
8 RL
VCC 2
7 RWB
CAT
I¯N¯C¯ 3
6 GND
U/D¯ 4
5 RH
PIN DESCRIPTION
I¯N¯C¯: Increment Control Input
The I¯N¯C¯ input (on the falling edge) moves the wiper in
the up or down direction determined by the condition
of the U/D¯ input.
U/D¯: Up/Down Control Input
The U/D¯ input controls the direction of the wiper
movement. When in a high state and C¯¯S is low, any
high-to-low transition on I¯N¯C¯ will cause the wiper to
move one increment toward the RH terminal. When in
a low state and C¯¯S is low, any high-to-low transition
on I¯N¯C¯ will cause the wiper to move one increment
towards the RL terminal.
RH: High End Potentiometer Terminal
RH is the high end terminal of the potentiometer. It is
not required that this terminal be connected to a
potential greater than the RL terminal. Voltage applied
to the RH terminal cannot exceed the supply voltage,
VCC or go below ground, GND.
RWB: Wiper Potentiometer Terminal (Buffered)
RWB is the buffered wiper terminal of the potentio–
meter. Its position on the resistor array is controlled by
the control inputs, I¯N¯C¯, U/D¯ and C¯¯S.
RL: Low End Potentiometer Terminal
RL is the low end terminal of the potentiometer. It is
not required that this terminal be connected to a
potential less than the RH terminal. Voltage applied to
the RL terminal cannot exceed the supply voltage, VCC
or go below ground, GND. RL and RH are electrically
interchangeable.
C¯¯S: Chip Select
The chip select input is used to activate the control
input of the CAT5112 and is active low. When in a
PIN DESCRIPTIONS
Name Function
I¯N¯C¯ Increment Control
U/D¯ Up/Down Control
RH Potentiometer High Terminal
GND Ground
RWB Buffered Wiper Terminal
RL Potentiometer Low Terminal
C¯¯S Chip Select
VCC Supply Voltage
high state, activity on the I¯N¯C¯ and U/D¯ inputs will not
affect or change the position of the wiper.
DEVICE OPERATION
The CAT5112 operates like a digitally controlled
potentiometer with RH and RL equivalent to the high
and low terminals and RWB equivalent to the mecha–
nical potentiometer's wiper. There are 32 available tap
positions including the resistor end points, RH and RL.
There are 31 resistor elements connected in series
between the RH and RL terminals. The wiper terminal
is connected to one of the 32 taps and controlled by
three inputs, I¯N¯C¯, U/D¯ and C¯¯S. These inputs control a
five-bit up/down counter whose output is decoded to
select the wiper position. The selected wiper position
can be stored in nonvolatile memory using the INC
and C¯¯S inputs.
With C¯¯S set LOW the CAT5112 is selected and will
respond to the U/D¯ and I¯N¯C¯ inputs. HIGH to LOW
transitions on I¯N¯C¯ wil increment or decrement the
wiper (depending on the state of the U/D¯ input and
five-bit counter). The wiper, when at either fixed
terminal, acts like its mechanical equivalent and does
not move beyond the last position. The value of the
counter is stored in nonvolatile memory whenever C¯¯S
transitions HIGH while the I¯N¯C¯ input is also HIGH.
When the CAT5112 is powered-down, the last stored
wiper counter position is maintained in the nonvolatile
memory. When power is restored, the contents of the
memory are recalled and the counter is set to the
value stored.
With I¯N¯C¯ set low, the CAT5112 may be deselected
and powered down without storing the current wiper
position in nonvolatile memory. This allows the system
to always power up to a preset value stored in non-
volatile memory.