English
Language : 

LC75814V Datasheet, PDF (11/14 Pages) Sanyo Semicon Device – 1/4 Duty General-Purpose LCD Driver
LC75814V
The INH pin and Display Control
Since the IC internal data (the display data D1 to D64 and the control data) is undefined when power is first applied,
applications should set the INH pin low at the same time as power is applied to turn off the display (This sets the S1/P1
to S4/P4, S5 to S16, and COM1 to COM4 to the VSS level.) and during this period send serial data from the controller.
The controller should then set the INH pin high after the data transfer has completed. This procedure prevents
meaningless displays at power on. (See Figure 3.)
Notes on the Power On/Off Sequences
Applications should observe the following sequence when turning the LC75814V power on and off.
• At power on: Logic block power supply (VDD) on → LCD driver block power supply (VLCD) on
• At power off: LCD driver block power supply (VLCD) off → Logic block power supply (VDD) off
However, if the logic and LCD driver block use a shared power supply, then the power supplies can be turned on and off
at the same time.
t1
VDD
t2
t3
VLCD
INH
CE
Internal data
D1 to D32
P0 to P2
DR, SC, BU
Internal data (D33 to D64)
Display and control data transfer
Undefined
VIL
tc
VIL
Defined
Undefined
Defined
Undefined
Note: t1 ≥ 0
t2 > 0
Undefined
t3 ≥ 0 (t2 > t3)
tc ... 10 µs min
Figure 3
ILC00278
Notes on Controller Transfer of Display Data
Since the LC75814V accept display data (D1 to D64) divided into two separate transfer operations, we recommend that
applications transfer all of the display data within a period of less than 30 ms to prevent observable degradation of
display quality.
No. 6792-11/14