MC10198 Datasheet, PDF (1/10 Pages) ON Semiconductor – Monostable Multivibrator | |||
|
MOTOROLA
SEMICONDUCTOR TECHNICAL DATA
Monostable Multivibrator
The MC10198 is a retriggerable monostable multivibrator. Two enable inputs
permit triggering on any combination of positive or negative edges as shown in
the accompanying table. The trigger input is buffered by Schmitt triggers
making it insensitive to input rise and fall times.
The pulse width is controlled by an external capacitor and resistor. The
resistor sets a current which is the linear discharge rate of the capacitor. Also,
the pulse width can be controlled by an external current source or voltage (see
applications information).
For highâspeed response with minimum delay, a hiâspeed input is also
provided. This input bypasses the internal Schmitt triggers and the output
responds within 2 nanoseconds typically.
Output logic and threshold levels are standard MECL 10,000. Test
conditions are per Table 2. Each âPreconditionâ referred to in Table 2 is per the
sequence of Table 1.
PD = 415 mW typ/pkg (No Load)
tpd = 4.0 ns typ Trigger Inpt to Q
2.0 ns typ HiâSpeed Input to Q
Min Timing Pulse Width
Max Timing Pulse Width
Min Trigger Pulse Width
Min HiâSpeed
Trigger Pulse Width
Enable Setup Time
Enable Hold Time
PWQmin
PWQmax
PWT
PWHS
tset
thold
1 CExt = 0 (Pin 4 open), RExt = 0
(Pin 6 to VEE)
2 CExt = 10 µF, RExt = 2.7 kâ¦
10 ns typ1
>10 ms typ2
2.0 ns typ
3.0 ns typ
1.0 ns typ
1.0 ns typ
LOGIC DIAGRAM
MC10198
L SUFFIX
CERAMIC PACKAGE
CASE 620â10
P SUFFIX
PLASTIC PACKAGE
CASE 648â08
FN SUFFIX
PLCC
CASE 775â02
DIP
PIN ASSIGNMENT
VCC1
Q
Q
CEXT
EPOS
REXT
EXT.PULSE
WIDTH CONTROL
VEE
1 16
2 15
3 14
4 13
5 12
6 11
7 10
89
VCC2
HIGHâSPEED
INPUT
N/C
TRIGGER INPUT
N/C
N/C
ENEG
N/C
VEE
VCC
6
4
REXT CEXT
5
E pos
Q
3
7
EXTERNAL PULSE
WIDTH CONTROL
VCC1 = PIN 1
10
ENEG
VCC2 = PIN 16
VEE = PIN 8
13
TRIGGER
INPUT
15
HIâSPEED
Q
2
INPUT
Pin assignment is for DualâinâLine Package.
For PLCC pin assignment, see the Pin Conversion
Tables on page 6â11 of the Motorola MECL Data
Book (DL122/D).
TRUTH TABLE
INPUT
OUTPUT
EPos ENeg
L L Triggers on both positive & negative input slopes
L H Triggers on positive input slope
H L Triggers on negative input slope
H H Trigger is disabled
3/93
© Motorola, Inc. 1996
3â172
REV 5
|
▷ |