English
Language : 

KAI-02150 Datasheet, PDF (1/42 Pages) ON Semiconductor – Interline CCD Image Sensor
KAI-02150
1920 (H) x 1080 (V) Interline
CCD Image Sensor
Description
The KAI−02150 Image Sensor is a 1080p (1920 × 1080) CCD in
a 2/3″ optical format. Based on the TRUESENSE 5.5-micron Interline
Transfer CCD Platform, the sensor features broad dynamic range,
excellent imaging performance, and a flexible readout architecture
that enables use of 1, 2, or 4 outputs for full resolution readout up to
64 frames per second. A vertical overflow drain structure suppresses
image blooming and enables electronic shuttering for precise exposure
control.
Table 1. GENERAL SPECIFICATIONS
Parameter
Architecture
Total Number of Pixels
Number of Effective Pixels
Number of Active Pixels
Pixel Size
Active Image Size
Typical Value
Interline CCD, Progressive Scan
2004 (H) × 1144 (V)
1960 (H) × 1120 (V)
1920 (H) × 1080 (V)
5.5 mm (H) × 5.5 mm (V)
10.56 mm (H) × 5.94 mm (V)
12.1 mm (Diagonal),
2/3″ Optical Format
Aspect Ratio
Number of Outputs
Charge Capacity
Output Sensitivity
Quantum Efficiency
Pan (−ABA, −PBA)
R, G, B (−FBA, −QBA)
R, G, B (−CBA, −PBA)
16:9
1, 2, or 4
20,000 electrons
34 mV/e−
44%
31%, 37%, 38%
29%, 37%, 39%
Base ISO
KAI−02150−ABA
KAI−02150−FBA
KAI−02150−CBA
KAI−02150−PBA
Read Noise (f = 40 MHz)
Dark Current
Photodiode/VCCD
330
170
150
330
12 e− rms
7/100 e−/s
Dark Current Doubling Temp
Photodiode/VCCD
7°C/9°C
Dynamic Range
Charge Transfer Efficiency
Blooming Suppression
Smear
Image Lag
Maximum Pixel Clock Speed
Maximum Frame Rate
Quad/Dual/Single Output
64 dB
0.999999
> 300 X
−100 dB
< 10 electrons
40 MHz
64/33/17 fps
Package
68 Pin PGA
64 Pin CLCC
Cover Glass
AR Coated, 2-Sides or Clear Glass
NOTE: All Parameters are specified at T = 40°C unless otherwise noted.
© Semiconductor Components Industries, LLC, 2015
1
April, 2015 − Rev. 6
www.onsemi.com
Figure 1. KAI−02150 Interline CCD
Image Sensor
Features
• Bayer Color Pattern, TRUESENSE Sparse
Color Filter Pattern, and Monochrome
Configurations
• Progressive Scan Readout
• Flexible Readout Architecture
• High Frame Rate
• High Sensitivity
• Low Noise Architecture
• Excellent Smear Performance
• Package Pin Reserved for Device
Identification
Applications
• Industrial Imaging
• Medical Imaging
• Security
ORDERING INFORMATION
See detailed ordering and shipping information on page 2 of
this data sheet.
Publication Order Number:
KAI−02150/D