E2C-ED02 Datasheet, PDF (9/15 Pages) Omron Electronics LLC – Proximity Sensor with Separate Amplifier Enables Easily Making High-precision Sensitivity Settings
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
Do not use this product in any safety device used for the
protection of human lives.
Precautions for Correct Use
Do not use this product in operating atmospheres or environments
outside the specified ratings.
Amplifier Units
Design
Power ON
The Sensor is ready to sense an object within 200 ms after turning the
power ON. If the load and Sensor are connected to different power
supplies, always turn ON the Sensor power first.
Cable
Use an external power cable of cross-section of 0.3 mm2 or more for
the Amplifier, and the total length of the cable must be 30 m or less.
Connecting Sensor Heads
Connecting and Disconnecting Sensor Heads
1. Open the protective cover.
2. Making sure that the lock button is up, insert the fibers all the way
to the back of the Connector insertion opening.
1
E2C-EDA
Connecting and Disconnecting Connectors
<Connecting Connectors>
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
Insert
2. Apply the supplied seal to the non-connection surface of the
Master/Slave Connector.
Protector seal
Power supply Connector
Note: Apply the seal to the grooved side.
<Disconnecting Connectors>
1. Slide the Slave Amplifier Unit.
2. After the Amplifier Unit has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Press down.
Lever
2
To disconnect the Sensor Head, pull out the fibers while pressing on
the lock button.
Lock button
Remove
Installing and Removing Amplifier Units
<Installing Amplifier Units>
1. Install the Units one by one to the DIN rail.
1
2
DIN rail
DIN rail
Sensor Head Connector Clips
2. Slide one Unit toward the other, match the clips at the front ends,
and then bring them together until they “click.”
1
1
2
<Removing Amplifier Units>
Slide one Unit away from the other and remove them one by one. (Do
not remove the connected Units together from the DIN rail.)
Note: 1. When the Amplifier Units are connected to each other, the
operable ambient temperature changes depending on the
number of connected Amplifier Units. Check
Specifications.
2. Before connecting or disconnecting the Units, always
switch power OFF.
9