XM2S-2511 Datasheet, PDF (8/8 Pages) Omron Electronics LLC – The D-sub Connector Series Enters a New Era with Lead-free Products.
TDe-xStub Connectors - XM3-L/XM2-L/XM4K/XM4L
■ Precautions
Correct Use
• Grounding (Lock Pin Grounding Fixture)
• To ground, provide copper foil around the Connector
Attachment hole on the board, assemble the connector and
grounding fixture, and dip in solder as shown below.
• Insert the connector into the PCB and then simultaneously
dip-solder the connector terminals and lock pin to the board.
Lock pin grounding fixture
PCB (t = 1.6 mm)
• Soldering
Automated Soldering Conditions
(Jet Flow)
1. Soldering temperature: 250 ±5˚C
2. Continuous soldering time: Within 5˚s
Approx. 1.9
• Tightening Torque of Anchor and Grounding
Fixture
If the anchor is secured to the connector, be sure to tighten it to
a torque of 0.49 N·m.
CAT NO. G922-E2-01
1049