English
Language : 

ZC-W55 Datasheet, PDF (6/7 Pages) Omron Electronics LLC – Small, High-precision ENclosed Switch
Mounting Holes
Two, 4.3 dia. mounting holes
or M4 screw holes
25.4±0.15
Molded Terminal Model
The molded-terminal model is available with right-hand, left-hand
and underside leads and is recommended for use where the switch
is exposed to dust, oil or moisture.
The molded-terminal model is not approved by UL and CSA.
ML
MR
MD
Ordering Information
Note: When placing your order for the switch, specify the required
length of V.S.F. or V.C.T. cable in addition to the model num-
ber of the switch.
Example:
Standard type:
ZC-Q2155
Location of lead output: Underside
Location of lead output
Right-hand
Left-hand
Underside
COM, NC, NO
ZC-j-MR
ZC-j-ML
ZC-j-MD
Pre-wired terminals: COM and NO
Length of lead:
1 m (V.C.T. lead)
When placing your order for the above switch, specify the model
number as ZC-Q2155-MD3 (VCT 1 m).
Suffix by Location of Lead Outlet
Suffix for pre-wired terminal
COM, NC
ZC-j-MR2
ZC-j-ML2
ZC-j-MD2
COM, NO
ZC-j-MR3
ZC-j-ML3
ZC-j-MD3
Lead Supplies
Leads
V.S.F.
(single-conductor
vinyl cable)
V.C.T. (vinyl cabtyre
cable)
Nominal
cross-sectional
area
1.25 mm2
No. of
component
wires/
component
wire diameter
50/0.18 dia.
Finished outside diameter
3.1 mm dia.
2 conductors
9.6 mm dia.
3 conductors
10.5 mm dia.
Terminal
connections
Standard
length
Black: COM
White: NO
Red: NC
1, 3, 5 m
Operation Indicator Equipped Model
All the models can be equipped upon request with a operation indi-
cator to facilitate maintenance and inspection.
Because the indicator is incorporated in the terminal protective cov-
er, the dimensions of the limit switch are not affected. In this model,
the lead wire is to be connected to the screw terminal. (A connecting
washer is provided on the tip of the lead wire).
The lead wire can be connected to either the NC or NO terminal.
Operating characteristics are the same as the standard model from
which the operation indicator equipped model is fabricated.
AC Operation
The operating voltage range is from 90 to 250 VAC.
The dimensions are the same as the standard type. The top of the
terminal protective cover is transparent to allow checking the opera-
tion easily.
When placing your order for the indicator equipped, AC-operated
model, add suffix “L” to the end of the model number.
Example:
Standard type:
ZC-Q2255
Indicator equipped type: ZC-Q2255-L
6