E2E Model Number Legend
E2E
E2E- A B C D E F G - H I - J - K - L M
No.
Classification
Code
Meaning
Remarks
A Appearance
C
Cylindrical (not threaded)
X
Cylindrical (threaded)
B Sensing distance
Number
R
Sensing distance (Unit: mm)
Indication of decimal point
Example:
R6: 0.6 mm
1R5: 1.5 mm
C Shielding
Blank
M
Shielded Models
Unshielded Models
B
DC 3-wire PNP open-collector output
C
DC 3-wire NPN open-collector output
D
Power supply and output
specifications
D
DC 2-wire polarity/no polarity
E
DC 3-wire NPN collector load built-in output
F
DC 3-wire PNP collector load built-in output
Whether D models have
polarity is defined by num-
ber J.
T
AC/DC 2-wire
Y
AC 2-wire
E
Form of output switching el-
ement
1
2
Normally open (NO)
Normally closed (NC)
F Oscillation frequency type
Blank
5
Standard frequency
Different frequency
Used to prevent mutual in-
terference.
G Self-diagnosis
Blank No
5
Yes
H Connection method
Blank
M1
M3
Pre-wired
M12-size metal connector
M8-size metal connector
These models are also
available with e-CON
connectors (0.3-m cable).
Add “-ECON” to the end of
the model number.
Blank
Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,
DC 2-wire with old pin arrangement (polarity)
G
Connector Models
DC 2-wire with IEC pin arrangement (polarity)
I Connector specifications
Pre-wired Connector Models
J
DC 3-wire and AC 2-wire, DC 2-wire with IEC pin arrangement
(polarity), DC 3-wire and AC 2-wire, DC 2-wire with self-diagno-
sis output, DC 2-wire with old pin arrangement (polarity)
GJ
Pre-wired Connector Models
DC 2-wire with IEC pin arrangement (polarity)
TJ
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (no polarity)
TGJ
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (polarity)
J DC 2-wire polarity
Blank
T
Polarity
No polarity
Blank Standard PVC cable (oil resistant)
K Cable specifications
R
Flexible PVC cable (oil resistant)
U
Polyurethane cable (oil resistant and reinforced)
L New model
N
New model (Applies only to DC 2-wire pre-wired and shielded
models.)
This is blank if the cable
specification in number K
is R or U.
M Cable length
Letter M
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre-
wired Connector Models.)
Example:
2M
0.3M
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
Models are not available for all combinations of code numbers.
Ask your OMRON representative if you require a customized model.