English
Language : 

D4NL_11 Datasheet, PDF (6/19 Pages) Omron Electronics LLC – Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models
D4NL
Characteristics
Degree of protection *1
Durability *2
Mechanical
Electrical
Operating speed
IP67 (EN60947-5-1)
1,000,000 operations min.
500,000 operations min. (3 A resistive load at 250 VAC) *3
0.05 to 0.5 m/s
Operating frequency
30 operations/minute max.
Direct opening force *4
Direct opening travel *4
Holding force *5
Contact resistance
60 N min. (EN60947-5-1)
10 mm min. (EN60947-5-1)
1,300 N min.
25 mΩ max. (per contact)
Minimum applicable load *6
Rated insulation voltage (Ui)
Rated frequency
1 mA resistive load at 5 VDC (N-level reference value)
300 V (EN60947-5-1)
50/60 Hz
Protection against electric shock
Class II (double insulation)
Pollution degree (operating environment) 3 (EN60947-5-1)
Between terminals of
same polarity
2.5 kV
Impulse withstand
voltage
(EN60947-5-1)
Between terminals of
different polarity
Between each
terminal and
non-current carrying
metallic parts
Insulation resistance
4 kV
6 kV
100 MΩ min. (at 500 VDC)
Contact gap
2 × 2 mm min.
Vibration
resistance
Shock resistance
Malfunction
Destruction
Malfunction
10 to 55 Hz, 0.75 mm single amplitude
1,000 m/s2 min.
100 m/s2 min.
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional free air thermal current (Ith)
Ambient operating temperature
10 A (EN60947-5-1)
−10 to 55°C (with no icing)
Ambient operating humidity
95% max.
Weight
Approx. 370 g (D4NL-1AFA-B)
Note: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however,
they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability
for smaller loads may be reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the
D4NL in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON
representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This figure is based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual
load beforehand.