English
Language : 

SS-10 Datasheet, PDF (5/8 Pages) Omron Electronics LLC – Subminiature Basic Switch
SS
Subminiature Basic Switch
Dimensions (Unit: mm) and Operating Characteristics
The illustrations and drawings are for solder terminals models.
Refer to "Terminals/Appearances" of the previous page for details on models with quick connect terminals (#110) or PCB terminals.
●Pin plunger
SS-10
SS-5 (-F)
SS-01 (-E, -F)
7.5
PT
2
3.2
A
OP
2.35+-00..00755
9.5 10.2
2.9
6.4
2.5
2.5±0.07 dia.
2.35+-00..00755 dia. holes
3.2 3-1.6 dia. holes
S
1.6
8.8
0.5
7.3
6.4
S
5.1 9.5±0.1
19.8
Model
Operating Characteristics
SS-10
SS-5
SS-01
SS-5-F
SS-01-F
SS-01-E
Operating Force
OF
Releasing Force
RF
Pretravel
PT
Overtravel
OT
Movement Differential MD
Operating Position OP
Max.
Min.
Max.
Min.
Max.
1.47 N {150 gf} 1.47 N {150 gf} 0.49 N {50 gf}
0.25 N {25 gf} 0.25 N {25 gf} 0.04 N {4 gf}
0.6 mm
0.4 mm
0.12 mm
0.5 mm
0.5 mm
0.1 mm
0.5 mm
0.5 mm
0.1 mm
8.4±0.5 mm
0.25 N {25 gf}
0.02 N {2 gf}
0.5 mm
0.5 mm
0.1 mm
●Hinge lever
SS-10GL
SS-5GL (-F)
SS-01GL (-E, -F)
●Long hinge lever
SS-10GL111
SS-5GL111 (-F)
SS-01GL111 (-E, -F)
t=0.3*
14.5
A
3.6
2.35+-00..00755
FP
OP
9.5 10.2
2.9
2.5
2.5±0.07 dia.
2.35+-00..00755 dia. holes
1.6
8.8
0.5
7.3
5.1 9.5±0.1
19.8
6.4
3.2 3-1.6 dia. holes
6.4
Note. The indicated reference values of RF are for cases
where the lever weight is not applied to the plunger.
* Stainless-steel lever
Operating Characteristics
Operating Force
OF
Releasing Force
RF
Model
Max.
Min.
SS-10GL
0.49 N {50 gf}
0.06 N {6 gf}
SS-5GL
SS-01GL
0.49 N {50 gf}
0.06 N {6 gf}
SS-5GL-F
SS-01GL-F
0.16 N {16 gf}
0.02 N {2 gf}
SS-01GL-E
0.08 N {8 gf}
0.01 N {1 gf}
(reference value)
Overtravel
OT
Movement Differential MD
Free Position
FP
Operating Position OP
Min.
Max.
Max.
1.0 mm
1.0 mm
1.2 mm
0.8 mm
1.2 mm
0.8 mm
13.6 mm
8.8±0.8 mm
1.2 mm
0.8 mm
t=0.3*
22.6
A
3.6
2.35+-00..00755
2.9
C
OP FP
9.5 10.2
NO
NC
2.5
2.5±0.07 dia.
1.6
8.8
5.1 9.5±0.1
19.8
2.35+-00..00575 dia. holes
0.5
7.3
* Stainless-steel lever
6.4
3.2 3-1.6 dia. holes
6.4
Note. The indicated reference values of RF are for cases
where the lever weight is not applied to the plunger.
Model
Operating Characteristics
Operating Force
Releasing Force
OF Max.
RF Min.
Overtravel
OT
Movement Differential MD
Free Position
FP
Operating Position OP
Min.
Max.
Max.
SS-10GL111
0.39 N {40 gf}
0.03 N {3 gf}
1.2 mm
1.2 mm
SS-5GL111 SS-5GL111-F
SS-01GL111 SS-01GL111-F
0.39 N {40 gf}
0.03 N {3 gf}
0.12 N {12 gf}
0.02 N {2 gf}
(reference value)
1.2 mm
1.2 mm
1.2 mm
1.2 mm
16.8 mm
8.8±1.5 mm
SS-01GL111-E
0.06 N {6 gf}
0.003 N {0.3 gf}
(reference value)
1.2 mm
1.2 mm
8.8±2 mm
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
5