■ Life-test Curve (Reference Value)
H3YN-2/-21
5,000
1,000
500
200
250 VAC, cosφ = 1
24 VDC, cosφ = 1
5,000
1,000
500
200
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
Load current (A)
Load current (A)
Reference:
A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 5 VDC (P reference value).
H3YN-4/-41
5,000
250 VAC, cosφ = 1
24 VDC, cosφ = 1
5,000
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
1,000
500
200
1,000
500
200
Load current (A)
Load current (A)
Reference:
A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 1 VDC (P reference value).
H3YN-4-Z/-41-Z
5,000
1,000
500
250 VAC, resistive load
100 24 VDC,
60 resistive load
Load current (A)
Reference:
A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 0.1 mA at 1 VDC (P reference value).
H3YN