E2E 2-WIRE AC
Operation
J OUTPUT CIRCUITS
Sensors without Short-Circuit Protection (E2E-XjYj)
E2E-XjYj-N AC 2-wire Models
Brown 1 (or 3)
Load
Main
circuit
Blue 2 (or 4)
AC 2-wire Models
E2E-XjYj-N
Sensing
object
Red
indicator
Control
output
Yes
No
Lit
Not lit
ON
OFF
Sensors with Short-Circuit Protection (E2E-XjYj-US-53)
White (Brown)
Load
Prox.
switch
main
circuit
Black (Blue)
E2E 2-WIRE AC
Note: IEC colors are shown in parenthesis
With Short-Circuit Protection
E2E-XjY1-53
NO
Load
Shorted
Normal
Target
Present
Absent
Output
ON
OFF
Output
operation
indicator
ON
OFF
E2E-XjY2-53
NC
Shorted
Normal
Present
Absent
ON
OFF
ON
OFF
Short-Circuit Indication
The LED dims when the load is shorted and the load output immediately turns off and remains off until the short-circuit protection is reset.
Resetting Short-Circuit Protection
Before the short-circuit protection can be reset, the short must be repaired. We recommend turning the power off before repairing the
short. If this approach is taken, no further action is required to reset the short-circuit protection.
If the short must be repaired with power on, the following resetting steps are required:
For NO sensors, the target must be removed to reset the short-circuit protection.
For NC sensors, the target must be presented then removed to reset the short-circuit protection.
6