D2F
Ultra Subminiature Basic Switch
●Hinge Roller Lever Models
D2F-L2@
D2F-01L2@
D2F-FL2@
D2F-01FL2@
12.8
(10)
4
A
4.8 dia.×2.8 *2
(4.6)
t=0.3 *1
4
FP
OP
Operating
Characteristics
Model D2F-L2@
D2F-FL2@
D2F-01L2@ D2F-01FL2@
Operating Force
Releasing Force
OF Max. 0.78 N {80 gf} 0.39 N {40 gf}
RF Min. 0.05 N {5 gf} 0.02 N {2 gf}
Overtravel
OT Min.
Movement Differential MD Max.
0.55 mm
0.5 mm
0.55 mm
0.5 mm
Free Position
FP Max.
16.5 mm
Operating Position OP
13±2 mm
D
2
F
*1. Stainless-steel lever
*2. Polyacetal resin roller
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
Precautions
★Please refer to "Basic Switches Common Precautions" for correct use.
Cautions
●Soldering
• Terminal connection
When soldering, make sure that the temperature of the
soldering iron tip is not higher than 300°C, and complete the
soldering within 3 seconds. Do not apply any external force for
1 minute after soldering. Soldering at an excessively high
temperature or soldering for more than 3 seconds may
deteriorate the characteristics of the Switch.
• Connecting to PCB terminal Boards
When using automatic soldering baths, we recommend
soldering at 260°C ±5°C within 5 seconds. Make sure that the
liquid surface of the solder does not flow over the edge of the
board.
When soldering terminals manually, perform soldering within 3
seconds at iron tip temperature not higher than 350°C. Do not
apply any external force for at least 1 minute after soldering.
When applying solder, keep the solder away from the case of
the Switch and do not allow solder or flux to flow into the case.
Correct Use
●Mounting
Use M2 mounting screws with plane washers or spring washers
to securely mount the Switch. Tighten the screws to a torque of
0.08 to 0.1 N·m {0.8 to 1 kgf·cm}.
●Using Micro Loads
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result in faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the following operating range, if inrush
current occurs when the contact is opened or closed, it may
increase the contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary. The
minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ60).
(JIS C5003)
The equation, λ60=0.5×10-6/operation, indicates that the
estimated malfunction rate is less than
1
2,000,000
operations
with a reliability level of 60%.
0.16 mA
30
16.6 mA 100 mA
24
Operating range
for micro load
models
D2F-01
Operating
range for
general-load
models
D2F
12
5
1 mA
0
0.1
1
10
100
1,000
Current (mA)
5