English
Language : 

G3VM-41AY1 Datasheet, PDF (4/8 Pages) Omron Electronics LLC – Small DIP4 package with Dielectric Strength of 5,000 VAC between I/O
G3VM-@AY@/@DY@
MOS FET Relays
■Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
zStandard type
Item
Load voltage (AC peak/DC)
Operating LED forward current
Symbol
G3VM-41AY1 G3VM-61AY1 G3VM-201AY1 G3VM-351AY1 G3VM-401AY1 G3VM-601AY1
G3VM-41DY1 G3VM-61DY1 G3VM-201DY1 G3VM-351DY1 G3VM-401DY1 G3VM-601DY1
Unit
VDD Maximum
32
Minimum
48
160
280
320
480
V
D
I
5
P
IF
Typical
7.5
mA
Maximum
25
Continuous load current (AC peak/DC)
IO
Maximum
2000
500
250
100
120
90
G
Minimum
−20
Ambient operating temperature
Ta
Maximum
65
°C
3
V
M
zHigh sensitive type
I
Item
Load voltage (AC peak/DC)
Operating LED forward current
Symbol
G3VM-41AY G3VM-61AY G3VM-201AY G3VM-351AY G3VM-401AY G3VM-601AY
G3VM-41DY G3VM-61DY G3VM-201DY G3VM-351DY G3VM-401DY G3VM-601DY
Unit
@
A
VDD Maximum
32
Minimum
48
160
280
320
480
V
Y
@
3
/
IF
Typical
5
mA @
Maximum
15
20
D
Continuous load current (AC peak/DC)
IO
Maximum
2000
500
250
100
120
90
Y
Minimum
−20
Ambient operating temperature
Ta
Maximum
65
@
°C
■Spacing and Insulation
zStandard type and High sensitive type
Item
Standard
Unit
Creepage distances
Minimum
7.0
Clearance distances
Minimum
7.0
mm
Internal isolation thickness
Minimum
0.4
4