English
Language : 

G3MB Datasheet, PDF (4/6 Pages) Omron Electronics LLC – Solid State Relay
■ Approvals
UL Recognized (File No. E64562) - - Ambient Temp. = 40°C
SSR Type
G3MB-102P
G3MB-202P
G3MB-202PL
G3MB-202PEG
G3MB-202PLEG
Input voltage
5 to 24 VDC
Load type
General purpose
Tungsten
Motor
General purpose
Tungsten
Motor
Load ratings
2 A, 120 VAC
1 A, 120 VAC
1.60 FLA/9.60 LRA, 120 VAC
2 A, 240 VAC
1 A, 240 VAC
1.60 FLA/9.60 LRA, 240 VAC
CSA Certified (File No. LR35535)
SSR Type
G3MB-102P
G3MB-202P
G3MB-202PL
Input voltage
5 to 24 VDC
Load type
General purpose
Tungsten
Motor
General purpose
Tungsten
Motor
Load ratings
2 A, 120 VAC
1 A, 120 VAC
1.60 FLA/8.60 LRA, 120 VAC
2 A, 240 VAC
1 A, 240 VAC
1.60 FLA/8.60 LRA, 240 VAC
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics
individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
Precautions
See General Information Section near the back of this catalog for
Solid State Precautions.
Make sure that the space between the bottom of the relay and the
PCB is 0.1 mm or less. When making holes on the PCB for the
relay’s edge terminals, the hole diameters should be slightly smaller
than the actual diameters of the edge terminals. This will reduce
unnecessary space between the bottom of the relay and the PCB.
To use the SSR output for phase control, select a model that does
not incorporate a zero-cross function.
The SSR case serves to dissipate heat. When mounting more than
three SSRs as a group, pay attention to the ambient temperature rise
and install the Relays so that they are adequately ventilated. If poor
ventilation is unavoidable, reduce the load current by half.
Protective Component
The input circuitry does not incorporate a circuit protecting the SSR
from being damaged due to a reversed connection. Make sure that
the polarity is correct when connecting the input lines.
Protective Element
No overvoltage absorption element is built in. Therefore, if the G3MB
is connected to an inductive load, be sure to connect the overvoltage
absorption element.
386
Solid State Relay G3MB