English
Language : 

G2R-1-TDC110 Datasheet, PDF (4/12 Pages) Omron Electronics LLC – Power PCB Relay
Latching dual coil type - Set coil
Rated voltage Rated current
(VDC)
(mA)
Coil
resistance
(Ω)
3
227
10.80
5
167
30
6
138
43.50
12
70.60
170
24
34.60
694
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
0.026
0.052
0.073
0.146
0.104
0.208
0.42
0.83
1.74
3.43
Pick-up
Dropout Maximum
Power
voltage
voltage
voltage consumption
% of rated voltage
(mW)
70% max.
70% max.
110% max.
at 70° C
(158° F)
Approx. 850
Latching dual coil type - Reset coil
Rated voltage Rated current
(VDC)
(mA)
Coil
resistance
(Ω)
3
200
15
5
119
42
6
100
60
12
50
240
24
25
960
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
0.001
0.002
0.003
0.006
0.005
0.009
0.018
0.036
0.079
0.148
Pick-up
Dropout Maximum
Power
voltage
voltage
voltage consumption
% of rated voltage
(mW)
70% max.
70% max.
110% max.
at 70° C
(158° F)
Approx. 600
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23° C (73° F) with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23° C (73° F).
■ Characteristics
Item
Contact resistance
Operate (set) time
Release (reset) time
Bounce time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Operate
Release
Mechanical
Electrical
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
Non-latching
Latching
100 mΩ
15 ms. max.
20 ms max.
AC: 10 ms max.; DC: 5 ms max.
20 ms max.
---
Mean value approx. 3 ms
---
Mean value approx. 8 ms
18,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute across contacts of same pole
3,000 VAC, 50/60 Hz for 1 minute between contact sets, 2-pole non-latching
1,000 VAC, 50/60 Hz for 1 minute between set and reset coils of dual coil latching
10 to 55 Hz; 1.50 mm (0.06) double amplitude
10 to 55 Hz; 1.50 mm (0.06) double amplitude
1,000 m/s2 (approx. 100G)
200 m/s2 (approx. 20 G) when energized
100 m/s2 (approx. 10 G) when de-energized
500 m/s2 (approx. 50 G) at set (1-pole)
200 m/s2 (approx 20G) at set (2-pole)
100 m/s2 (approx. 10 G) at reset
-40 to 70° C (-40 to 158° F)
5% to 85% RH
10,000,000 operations min.
DC: 20,000,000 operations min.
(at 18,000 operations/hour)
10,000,000 operations min.
(at 18,000 operations/hour)
100,000 operations min. (at 1,800 operations /hr) at rated load. See “Characteristics Data”
Approx. 17 g (0.60 oz.)
Approx. 17 g.
(Approx 20g for quick-connect type)
Note: Data shown are of initial value.
212
Power PCB Relay G2R