English
Language : 

E3C-WE4 Datasheet, PDF (4/16 Pages) Omron Electronics LLC – Thin, Compact Head Saves Space and Mounts Closely. Built-in Interference Protection Provided.
E3C
Amplifier Units
Item
Model
E3C-A
E3C-C
E3C-JC4P
E3C-GE4
Power supply
voltage
100 to 240 VAC±10%, 50/60 Hz
12 to 24 VDC±10%, ripple (p-p): 1 V max.
Power (current)
consumption
3 W max.
50 mA max.
Control
output
Transis-
tor
output
Load power supply voltage: 24 VDC max., load current: 80 mA
max., voltage output type, output current: 1 to 4 mA (residual
voltage: 1.2 V max.)
Light-ON/Dark-ON switch selectable
Load power supply voltage: 24
VDC max., load current: 100
mA max., NPN open collector
output type (residual voltage:
1 V max.)
Light-ON/Dark-ON switch se-
lectable
Load power supply voltage: 24
VDC max., load current:
80 mA max., voltage output
type, output current: 1 to 4 mA
(residual voltage: 0.7 V max.)
Light-ON/Dark-ON cable con-
nection selectable
Relay out-
put
220 VAC 1 A cosφ=1
(resistive load)
SPDT contact only
---
H = 6 to 30 V
External
synchronous input
---
L = 0 to 2 V
When L, turns OFF the control
---
output forcibly.
Timer function
---
ON/OFF, oneshot delay (se- OFF-delay 0/40 ms (switch se-
lectable): 1 or 10 s max.
lectable)
---
Ambient
temperature range
Operating: −10° to 55°C, Storage: −25° to 70°C (with no icing or condensation)
Ambient humidity
range
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC
Dielectric strength
500 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 300 ms2 three times in each of X, Y and Z directions
Degree of protection
IEC IP20
(limited to indoor use)
IEC IP60
(limited to indoor use)
IEC IP20
(limited to indoor use)
Protection
Reverse polarity protection, output short-circuit protection, mutual interference prevention
Response
time
No
contact
Relay
Operate or reset: 1 ms max./2 ms max. each (switch select-
able)
Operate or reset: 20 ms max.
Operate or reset: 1 ms max.
Operate or reset: 1 ms max./2 ms
max. each (switch selectable)
---
Connection method Terminal block
Terminal block input cable
pullout
(standard cable length: 2 m)
Terminal block
Weight
(packed state)
Approx. 200 g
Approx. 80 g
Approx. 15 g
Material
Case
Mounting
Brackets
ABS
Stainless steel
---
Iron
Polycarbonate
---
Accessories
Connection Socket (PF113A)
Instruction manual
Mounting Bracket, Adjustment
screwdriver, Caution label,
Instruction manual
Instruction manual
* The terminal pins are used for connection between amplifiers for synchronous operation.
4