English
Language : 

E53-CN03N2 Datasheet, PDF (30/72 Pages) Omron Electronics LLC – Digital Temperature Controllers/Digital Controllers
E5AN/E5EN
Waterproof Packing
Y92S-P4 (for DIN 96 × 96)
Y92S-P5 (for DIN 48 × 96)
Order the Waterproof Packing separately if it becomes lost or
damaged.
The Waterproof Packing can be used to achieve an IP66 degree of
protection.
(Deterioration, shrinking, or hardening of the waterproof packing may
occur depending on the operating environment. Therefore, periodic
replacement is recommended to ensure the level of waterproofing
specified in IP66. The time for periodic replacement depends on the
operating environment. Be sure to confirm this point at your site.
Consider one year a rough standard. OMRON shall not be liable for
the level of water resistance if the customer does not perform periodic
replacement.)
The Waterproof Packing does not need to be attached if a waterproof
structure is not required.
Current Transformers
E54-CT1
25 3
10
E54-CT3
40 × 40
21
15
5.8 dia.
2.8
7.5
10.5
40
Two, 3.5 dia.
30
2.36 dia.
30
12 dia.
9
E54-CT3 Accessory
• Armature
Approx. 3 dia.
Two, M3 (depth: 4)
15
30
Connection Example
Plug
Armature
Lead
• Plug
Approx. 6 dia.
18
(22)
E54-CT1
Thru-current (Io) vs. Output Voltage
(Eo) (Reference Values)
Maximum continuous heater current: 50 A (50/60 Hz)
Number of windings: 400±2
Winding resistance: 18±2 Ω
100 V 50 Hz
10
1
100 mV
∞
1 kΩ
Distortion
factor 10%
3%
1%
10
100 Ω
1
RL = 10 Ω
100 µV
10
1
10 100 mA 1
10
100 1,000 A
Thru-current (Io) A (r.m.s.)
E54-CT3
Thru-current (Io) vs. Output Voltage
(Eo) (Reference Values)
Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for an OMRON
Temperature Controller is 50 A.)
Number of windings: 400±2
Winding resistance: 8±0.8 Ω
100 V 50 Hz
10
1
∞
1 kΩ
500 Ω
Distor-
tion
factor
10%
3%
1%
100 mV
10
1
100 Ω
50 Ω
RL = 10 Ω
100 µV
10
1
10 100 mA
1
10
100 1,000 A
Thru-current (Io) A (r.m.s.)
30