English
Language : 

G9YA12S45DC12 Datasheet, PDF (3/10 Pages) Omron Electronics LLC – High-frequency, High-capacity Coaxial Switch Supporting Bandwidths to 26.5 GHz
Specifications
DISCONTINUED
■ Indicator Ratings, SPDT Models
Rating
Contact resistance
100 mA max. at 30 V
1 Ω max. (See note 2.)
Note: 1. The above values are initial values.
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
■ High-frequency Characteristics
Frequency 1 GHz max.
4 GHz max.
8 GHz max.
12.4 GHz max. 18 GHz max. 26.5 GHz max.
Item
Insertion loss
0.2 dB max.
0.3 dB max.
0.4 dB max.
0.5 dB max.
0.8 dB max.
Isolation
85 dB min.
80 dB min.
70 dB min.
65 dB min.
60 dB min.
V.S.W.R.
1.1 max.
1.15 max.
1.25 max.
1.35 max.
1.5 max.
1.7 max.
Note: 1. The above values are initial values.
2. Of the above values, the rated values are 18 GHz max. for the 18-GHz models and 26.5 GHz max. for the 26.5-GHz models.
■ Coil / Input Ratings
Note: An extra 140 to 300 mW of power consumption is added to models with indicator terminals, due to the operating coil and voltage specifications.
Failsafe Models (G9YA-12S-45(35))
Rated voltage Rated current Coil resistance Must operate voltage Must release voltage Maximum voltage Power consumption
(VDC)
(mA)
(W)
(V)
(V)
(V)
(mW)
4.5
155.2
29
80% max. of
10% min. of
150% of rated voltage Approx. 700
12
58.5
205
rated voltage
rated voltage
15
46.7
321
24
29.2
822
28
25.0
1,118
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Dual Coil Latching Models (G9YAK-12S-45(35))
Rated voltage Rated current Coil resistance Must operate voltage Must release voltage Maximum voltage
(VDC)
(mA)
(W)
(V)
(V)
(V)
4.5
109.8
41
80% max. of
80% max. of
150% of
12
41.7
288
rated voltage
rated voltage
rated voltage
15
33.3
450
24
20.8
1,152
28
17.9
1,568
Power consumption
(mW)
Approx. 500 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
TTL-driven Dual Coil Latching Models (G9YAT-12S-45(35))
Rated voltage
(VDC)
ON
5 VDC
2.4 to 5.5 V
12 VDC
15 VDC
24 VDC
TTL logic level
0 to 0.5 V
OFF
Electronic self cut-off
Switching frequency
Yes
180 operations per
minute max.
(ON time: OFF time = 1:1)
Coaxial Switch G9YA 359