G6S Datasheet, PDF (3/12 Pages) Omron Electronics LLC – Low Signal Relay
■ Characteristics
Contact resistance (See note 1)
Operate (set) time (See note 2)
Release (reset) time (See note 2)
Bounce time
Max. operating frequency
Insulation resistance (See note 3)
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Ambient Humidity
Service life
Conforming to
Telcordia specs.
Conforming to
FCC Part 68
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
Weight
75 mΩ max.
4 ms max. (mean value approx. 2.5 ms G6S; 2.0 ms G6SU, G6SK)
4 ms max. (mean value approx. 1.5 ms G6S; 2.0 ms G6SU, G6SK)
Approx. 0.5 ms
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute (G6S, G6SU) between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute (G6SK) between coil and contacts
1,500 VAC, 50/60 Hz for 1 minute between contacts of different poles
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
500 VAC, 50/60 Hz for 1 minute between set and reset coils (G6SK)
2,500 V (2 x 10 μS) between coil and contacts for G6S and G6SU
2,500 V (2 x 10 μS) between contacts of different poles
1,500 V (10 x 160 μS) between coil and contacts for G6SK
1,500 V (10 x 160 μS) between contacts of same pole
10 to 55 Hz; 5 mm double amplitude
10 to 55 Hz; 3.3 mm double amplitude
1,000 m/s2; approx. 100 G
750 m/s2; approx. 75 G
-40 to +85°C with no icing; -40 to +70°C with no icing (G6SK, DC24 coil)
5% to 85% RH
100,000,000 operations min. (at 36,000 operations/hour)
100,000 operations min. (2A@30VDC, resistive; 1,200 ops/hr.)
100,000 operations min. (0.5A@125VAC, resistive)
See “Characteristic Data”
Approx. 2g
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
the dielectric strength (except between the set and reset coil).
4. Data shown are of initial value.
■ Characteristic Data
Service Life
1000
1000
1000
500
500
500
300
300
300
200
200
200
100
100
100
50
50
50
30
30
30
20
20
20
10
0
0.2
0.4
0.6
0.8
1.0
Service life (x106 operations)
Resistive load: 10 mA, 10 VDC
Ambient temperature: +85˚
10
0
0.1
0.2
0.3
0.4
0.5
Service life (x106 operations)
Resistive load: 100 mA, 28 VDC
Ambient temperature: +85˚
10
0
0.2
0.4
0.6
0.8
1.0
Service life (x106 operations)
Resistive load: 100 mA, 50 VDC
Ambient temperature: +85˚
Low Signal Relay G6S
97