English
Language : 

G3VM-401G_10 Datasheet, PDF (3/4 Pages) Omron Electronics LLC – MOS FET Relays
■ Engineering Data
LED forward current vs.
Ambient temperature
IF - Ta
100
80
60
40
20
0
−20
0
20
40
60
80 100 120
Ambient temperature Ta (ഒ)
Continuous load current vs.
On-state voltage
IO - VON
200
Ta = 25°C
IF = 5 mA
100
0
−100
−200
−3
−2
−1
0
1
2
3
On-state voltage VON (V)
Turn ON, Turn OFF time vs.
LED forward current
tON, tOFF - IF
2000
tON
1000
Ta = 25°C
VDD = 20 V, RL = 200 Ω
500
300
100
tOFF
50
30
1
35
10
30 50 100
LED forward current IF (mA)
Continuous load current vs.
Ambient temperature
IO - Ta
280
240
200
160
120
80
40
0
−20
0
20
40
60
80 100 120
Ambient temperature Ta ഒ
On-state resistance vs.
Ambient temperature
RON - Ta
60
IO = 120 mA
IF = 5 mA
50
40
30
20
10
0
−20
0
20
40
60
80
100
Ambient temperature Ta (ഒ)
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - Ta
1000
VDD = 20 V, RL = 200 Ω
IF = 5 mA
800
tON
600
400
200
tOFF
0
−40 −20
0
20
40
60
80 100
Ambient temperature Ta (ഒ
LED forward current vs.
LED forward voltage
IF - VF
100
Ta = 25°C
50
30
10
5
3
1
0.5
0.3
0.1
0.6
0.8
1
1.2
1.4
1.6
1.8
LED forward voltage VF (V)
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
5
IO = 120 mA
t<1s
4
3
2
1
0
−40 −20
0
20
40
60
80 100
Ambient temperature Ta (ഒ)
Current leakage vs.
Ambient temperature
I LEAK - Ta
1000
VOFF = 400 V
500
300
100
50
30
10
5
3
1
−20
0
20
40
60
80
100
Ambient temperature Ta (ഒ)
MOS FET Relays G3VM-401G 217