English
Language : 

G2RL-24-CFDC5 Datasheet, PDF (3/6 Pages) Omron Electronics LLC – A Power Relay with Various Models
■ Approved Standards
UL Recognized (File No. E41643) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Model
Contact form
Coil ratings
Contact ratings
G2RL-1A
SPST-NO
3 to 48 VDC
12 A at 250 VAC (General use)
G2RL-1
SPDT
12 A at 24 VDC (Resistive)
G2RL-1A-E
SPST-NO
3 to 48 VDC
16 A at 250 VAC (General use)
G2RL-1-E
SPDT
16 A at 24 VDC (Resistive)
G2RL-1A-H
G2RL-1-H
SPST-NO
SPDT
5 to 24 VDC
10 A at 250 VAC (General use)
10 A at 24 VDC (Resistive)
G2RL-2A
G2RL-2
DPST-NO
DPDT
3 to 48 VDC
8 A at 277 VAC (General use)
8 A at 30 VDC (Resistive)
Note: Consult Omron for additional UL / CSA ratings
VDE (EN61810-1) (License No. 119650)
Model
Contact form
G2RL-1(A)
1 pole
G2RL-1(A)-E
1 pole
G2RL-1(A)-H
G2RL-2(A)
1 pole
2 poles
Coil ratings
5, 12, 18, 22, 24, 48 VDC
5, 12, 18, 22, 24, 48 VDC
5, 9, 12, 24 VDC
5, 12, 18, 22, 24, 48 VDC
Contact ratings
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
DC13: 2.5 A at 24 VDC (NO), 50 ms
10 A at 250 VAC (cosφ=1)
10 A at 24 VDC (L/R=0 ms)
8 A at 250 VAC (cosφ=1)
8 A at 24 VDC (L/R=0 ms)
AC15: 1.5 A at 240 VAC
DC13: 2 A at 30 VDC, 50 ms
Note: To achieve approved life cycles on sealed models, the relay should be vented by removing the “knock off vent nib” on top of relay case after
the soldering/washing process.
Electrical Life Data
G2RL-1-E
G2RL-1
G2RL-1-H
G2RL-2
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC
8 A at 250 VAC (cosφ=0.4)
8 A at 30 VDC (L/R=7 ms)
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC
5 A at 250 VAC (cosφ=0.4)
5 A at 30 VDC (L/R=7 ms)
10 A at 250 VAC (cosφ=1)
10 A at 24 VDC
8 A at 250 VAC (cosφ=1)
8 A at 30 VDC
30,000 operations min.
30,000 operations min.
200,000 operation min. (normally open side operation)
10,000 operation min. (normally open side operation)
50,000 operations min.
30,000 operations min.
150,000 operation min. (normally open side operation)
20,000 operation min. (normally open side operation)
100,000 operations min.
50,000 operations min.
30,000 operations min.
30,000 operations min.
Note: 1. The results shown reflect values measured using very severe test conditions i.e., Duty: 1 s ON/1 s OFF.
2. In order to obtain the full rated life cycles on the fully sealed models, the relay should be properly vented by removing the “knock off vent
nib” on top of the relay case after the soldering/washing process.
3. Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed
information for the electrical endurance under your test conditions.
PCB Relay G2RL 223