■ Accessories
It is recommended that the following accessories be used for mounting Temperature Sensors.
Accessory
Compression
Fitting
Temperature
range
600°C max.
Mounting with
Compression
Fitting
Mounting example
Compression Fitting
Terminal box
Page
30
PT screw
Welding
Loose Flange 400°C max.
Mounting with
Loose Flange
Loose Flange
Mounting screw
Protective tubing
Terminal box
Protective tubing
Note: The Compression Fitting is not
of airtight construction. Do not
use the Compression Fitting for
applications in which the
exposure of the sensing object
will cause problems.
Note: 1. Use the Loose Flange in
normal atmospheric
pressure. The Loose
Flange is not of airtight
construction.
2. Use the Loose Flange at
400°C max.
3. Do not apply the Loose
Flange to protective tubing
diameters other than the
applicable ones.
■ Lead Wires
Accessory
For resistance ther- Standard
mometers
Heat resistive
For thermocouples
(compensating con-
ductor)
Standard
Heat resistive
Specification
Temperature range
Vinyl-covered with twelve 0.18-dia. conductors (0.3 mm thick) and
4.8 mm in outer dia.
−20°C to 70°C
Glass-wool-covered with twenty 0.18-dia. conductors (0.5 mm thick) ex- 0°C to 180°C
ternally shielded with stainless steel, 5.2 mm in outer dia.
Sleeve: 0°C to 100°C
Vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and 3.2 x −20°C to 70°C
5.0 mm in outer dia.
Glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) exter- 0°C to 150°C
nally shielded with stainless steel, 2.9 x 4.6 mm in outer dia.
Sleeve: 0°C to 100°C