English
Language : 

E3XDA51S2M Datasheet, PDF (29/35 Pages) Omron Electronics LLC – Evolution and Perfection The next-generation platform for a wide range of sensing
Nomenclature
Amplifier Units
E3X-DA@-S
E3X-DA@RM-S
E3X-DA@AN-S
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings,
etc.
Lock lever
Locks the fiber.
Operation Keys
Function setting operations
UP
DOWN
MODE
E3X-DA-S/MDA
E3X-DA@TW-S
E3X-DA@AT-S
E3X-MDA@
Main Display (Red)
Incident level, function, etc.
Lock lever
Locks the fiber.
Sub-Display (Green)
Threshold, function settings,
etc.
Operation Keys
Function setting operations
UP
DOWN
MODE
Operation Indicator
(orange)
ON when output is
ON.
OFF when output is
OFF.
Power Tuning Indicator
ON: Power tuning is set.
Operation Selector
Use to switch between Light
ON and Dark ON modes.
Mode Selector
Use to select SET or RUN mode.
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
Amplifier Unit
● Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power supply is
turned ON. If the Sensor and load are connected to separate power
supplies, be sure to turn ON the Sensor first.
● Mounting
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
Operation indicator for
channel 1 (orange)
ON when output is ON.
OFF when output is OFF.
Channel Selector
Operation indicator for
channel 2 (orange)
Use to switch between channels
1 and 2.
Mode Selector
ON when output is ON. Use to select SET or RUN mode.
OFF when output is OFF.
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit(s) has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Press down
Lever
Remove
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
Insert
2. Attach the protector seals (provided as accessories) to the sides of
master and slave connectors that are not connected.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Click into place
Seal
Seal
Note: Attach the seals to the sides with grooves.
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
Note: 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before joining or separating
Amplifier Units.
15