A22-TG-11A Datasheet, PDF (25/36 Pages) Omron Electronics LLC – Install in 22-dia. or 25-dia. Panel Cutout
x Tighten the mounting nut at a torque of 0.98 to 1.96 N·m.
x When using a Lock Ring, replace with the supplied Lock Ring,
insert the projecting part into the lock slot, and then tighten the
mounting nut.
Hold here
Rubber washer
Mounting nut
Panel
Projecting
part
Mounting/Replacing the Color Cap
Projection, Fall-guard
x Grip and rotate the Color Cap with your fingers.
A22
Lock Ring
Panel
Lock Ring
x When the panel cutout dimension is 25 dia., remove the supplied
rubber washer and mount the 25-dia. Ring as shown below. (Since the
A22Z-R25 is not attached to the main body, order separately.)
Operation Unit
Half-guard Indicators
x Put the tips of the Cap Tightening Tool (A22Z-3908) into the Color
Cap slot and turn the Tool.
22 dia.
25-dia. Ring (A22Z-R25)
22.3 dia.
25 dia.
0.5 1.3
Assembling the Cap
Lighted Pushbutton Switch
x Mount the Color Cap so that the protrusions inside the cap fit into
the grooves in the Pushbutton Unit.
Panel
25 dia.
Lock Ring
22.3 dia.
Mounting nut
Mounting the Switch on the Pushbutton Unit
x Insert the Pushbutton Unit into the Switch Unit, aligning the arrow
mark inscribed on the Case with the lever on the Switch Blocks,
then move the lever in the direction indicated by the arrow in the
following figure.
Operation Unit
Arrow mark
Lever
Removing the Switch
x Move the lever in the
direction indicated by the
arrow in the following figure,
then pull the Pushbutton
Unit or the Switch Blocks.
Since the lever has a hole
with an inside diameter of
6.5 mm, the lever can be
moved in the specified
direction by inserting a
screwdriver into the hole and
then moving the
screwdriver.
Screwdriver
Protrusion
inside cap
Color Cap
Indicator
x Mount the Color Cap so that the protrusions inside the Pushbutton
Unit fit into the grooves in the cap.
Cap
Protrusion
Grooves
Color Cap
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.