English
Language : 

WLF2CA2-2 Datasheet, PDF (22/43 Pages) Omron Electronics LLC – Wide Range of Two-circuit Switches; Select One for the Operating Environment/Application
WL/WLM
Long-life Switches
Ratings
General Ratings (Refer to these ratings before using the product.)
Screw Terminal Switches
Item
Model
Basic models,
overtravel mod-
els, (except for
high-sensitivity
models), and
high-precision
models
High-sensitivity
overtravel mod-
els
Rated
voltage
(V)
115 AC
12 DC
24 DC
48 DC
115 DC
115 AC
115 DC
Non-inductive load (A)
Resistive
load
Lamp
load
NC NO NC NO
10
3 1.5
10
63
6
43
3
2 1.5
0.8
0.2 0.2
5
—
0.4
—
Inductive load (A)
Induc- Motor
tive load load
NC NO NC NO
10
5 2.5
10
6
6
4
3
2
0.8
0.2
—
—
—
—
Inrush NC
current NO
30 A max. (15 A max. *)
20 A max. (10 A max. *)
* For high-sensitivity overtravel models.
Direct-wired Connector and Pre-wired Connector Switches
Rated
Model voltage
(V)
12 DC
24 DC
DC
48 DC
115 DC
AC 115 AC
Non-inductive load (A)
Resistive
load
Lamp load
NC NO NC NO
3
3
3
3
3
3
3
3
3
3
3
3
0.8 0.8 0.2 0.2
3
3
3 1.5
Inductive load (A)
Inductive
load
Motor load
NC NO NC NO
3
3
3
3
3
3
3
3
3
3
3
3
0.8 0.8 0.2 0.2
3
3
3 2.5
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Characteristics
Degree of protection
IP67
Mechanical 30,000,000 operations min.
Durability *
Electrical
30,000,000 operations min. (10 mA at
24 VDC, resistive load)
750,000 operations min. (10 A at 115
VAC, resistive load), but for high-pre-
cision models: 500,000 operations
min. (10 A at 115 VAC, resistive load)
Operating speed
1 mm/s to 1 m/s (in case of WLCA2)
Operating
frequency
Mechanical 120 operations/minute
Electrical 30 operations/minute
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
25 mΩ max. (initial value for the built-
in switch when tested alone)
Between
terminals of
the same
polarity
1,000 VAC (except connector models)
Dielectric
strength
(50/60 Hz
for 1 min)
Between
current-
carrying
metal part
and ground
2,200 VAC (1,500 V)
Between each
terminal and
non-current-
carrying metal
part
2,200 VAC (1,500 V)
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock
Destruction 1,000 m/s2 min.
resistance Malfunction 300 m/s2 min.
Ambient operating
temperature
–10°C to +80°C (with no icing)
Ambient operating
humidity
35% to 95%RH
Weight
Approx. 275 g (in case of WLCA2)
Note: The figures in parentheses for dielectric strength, are those for overtravel
(high-sensitivity) or connector models.
* The values are calculated at an operating temperature of +5°C to +35°C, and
an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
Engineering Data
Electrical Durability: cosφ= 1
(Operating temperature: +5°C to +35°C, operating humidity: 40% to
70%RH)
1,000
500 125 VAC
Operating frequency:
30 operations/min cos φ= 1
300
250 VAC
100 480 VAC
50
30
10
0
2
4
6
8
10 12
Switching current (A)
22