H7CX Datasheet, PDF (22/43 Pages) Omron Electronics LLC – Multifunction Preset Counter
Settings for All Functions
Note: At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration. When using
as a 2-stage (or 1-stage) counter, total and preset counter, batch counter, or dual counter, switch to the configuration using the procedure
given on page 124.
Settings that cannot be performed with the DIP switch are performed with the operation keys.
Power ON
See note 1.
3 s min.
See note 2.
3 s min.
See note 3.
Input mode
Output mode
See note 6.
One-shot
output
time
Counting
speed
Reset input
signal
width
For details on operations in run mode, refer to page 25.
Note: 1. If the mode is switched to the function setting mode during operation, operation will con-
tinue.
2. Changes made to settings in function setting mode are enabled for the first time when the
mode is changed to run mode. Also, when settings are changed, the counter is reset
(present value initialized and output turned OFF) on returning to run mode.
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed.
Set each setting item using the r keys. ( key only for 6-digit models)
See note 4. See note 4.
Note 3:
When using as a dual counter:
Dual count
calculating mode
(UP)
(DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C)
Note 4: Displayed for output modes other than K-2, D, L, and H only.
See note 5. See note 5.See note 5.See note 5.
See note.
(Addition) (Subtraction)
Note: Displayed for output modes
other than K-2, D, L, and H
only.
(N) (F) (C) (R)
(K-1)
(P) (Q) (A)
(K-2)
(D) (L) (H)
Note: 5. Display only when the input mode is UP/DOWN A, B,
or C with 6-digit models (with H7CX-AU@/-AW@
models only for H).
(0.01s) (0.50s) (99.99s)
Note: Displayed only when the output mode is C, R, K-1, P,
Q, A, or K-2.
(30Hz)
(5kHz)
Note 6:
When using as a 2-stage counter:
One-
shot
output
(0.01s) (0.50s) (99.99s)
2 time Note: Displayed only when the
output mode is C, R, K-1,
P, Q, A, or K-2.
One-
shot
output (Outputs held) (0.01s) (99.99s)
1 time
If the output time is 0.00, hold is
displayed.
Note 1: Displayed for output modes
When using as a
batch counter:
other than D, L, and H.
Note 2: HOLD cannot be set when the
output mode is K-2.
(20ms)
(1ms)
One-
shot
output
2 time
(0.01s) (0.50s) (99.99s)
Note: Displayed only when the output
mode is C, R, K-1, P, Q, A, or K-2.
Decimal
point
position
Prescale
value
NPN/PNP
input mode
See note 7.
No decimal
point
One digit after
decimal point
See note 7.
∼∼
(0.001)
(1.000)
(99.999) [9.999]
Two digits after
decimal point
Three digits after
decimal point
Note 7: The displays for 4-digit models are shown inside
parentheses.
Display color
(NPN
input)
(PNP
input)
Output
allocation
(Red) (Green) (Red-green) (Green-red)
Note: Displayed for terminal-block models (except H7CX-A11@) only.
Note: Displayed for H7CX-AU@ models only.
Key protect
level
(KP-1)
(KP-2)
(KP-3)
(KP-4)
(KP-5)
C-108 Multifunction Preset Counter H7CX (Counter Function)