English
Language : 

ZC-D55_06 Datasheet, PDF (2/8 Pages) Omron Electronics LLC – Small, High-precision ENclosed Switch
Specifications
Approved Standards
Agency
UL*
TÜV Rheinland
CCC(CQC)
Standard
UL508
EN60947-1, EN60947-5-1
GB14048.5
File No.
E76675
J50041904
2003010303077620
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
Ratings
Non-inductive load (A)
Rated
voltage
Resistive load
Lamp load
NC NO NC NO
125 VAC 10
250 VAC 10
3
1.5
2.5 1.25
8 VDC 10
14 VDC 10
30 VDC 6
125 VDC 0.5
250 VDC 0.25
3
1.5
3
1.5
3
1.5
0.4 0.4
0.2 0.2
Inductive load (A)
Inductive load Motor load
NC NO NC NO
10
5
2.5
10
3
1.5
6
5
2.5
6
5
2.5
5
5
2.5
0.05
0.05 0.05
0.03
0.03 0.03
Inrush NC
current NO
30 A max.
15 A max.
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions
according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.
Characteristics
Degree of protections
IP67
Mechanical
Durability
Electrical
10,000,000 operations min.
500,000 operations min.
Operating speed
0.05 mm/s to 0.5 m/s *1
Operating Mechanical
frequency Electrical
Insulation resistance
Contact resistance
120 operations/min
20 operations/min
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value for the built-
in switch when tested alone)
Dielectric
strength
Between non-continu-
ous terminals
Between each terminal
and non-current-carry-
ing metal parts
1,000 VAC, 50/60 Hz for 1 min
2,000 VAC, 50/60 Hz for 1 min
Rated insulation voltage (Ui)
1,000 VAC
Pollution degree
(operating environment)
3 (IEC947-5-1)
Short-circuit protective device
10 A-fuse type gG (IEC 60269)
Protection against electric shock Class II
Proof tracking index (PTI)
175
Switch category
D (IEC335)
Rated operating current (Ie)
10 A
Rated operating voltage (Ue)
250 VAC
Vibration
resistance
Malfunction
10 to 55 Hz, 1.5-mm double ampli-
tude *2
Shock
Destruction
resistance Malfunction
Ambient operating temperature
Ambient operating humidity
1,000 m/s2 max.
300 m/s2 max.
(in case of plunger model) *1 *2
−10°C to +80°C (with no icing)
35% to 95%RH
Weight
Approx. 92 g (in case of ZC-
Q22(21)55)
*1. Only for models with plungers. (Contact your OMRON representative for
information on other models.)
*2. Less than 1 ms under a free state at the operating limits.
ZC-@55
Approved Standard Ratings
UL/CSA
A300
Voltage
120 VAC
240 VAC
Carry
current
10A
Current (A)
Make
60
30
Break
6
3
Volt-amperes
(VA)
Make Break
7,200 720
TÜVRheinland (EN60947-1, EN60947-5-1),
CCC (GB14048.5)
Applicable category and ratings
AC-12 10 A/250 VAC
Engineering Data
Electrical Durability
10,000
7,000
5,000
3,000
1,000
700
500
300
125 VAC cosφ=1
125 VAC cosφ=0.4
250 VAC cosφ=1
250 VAC cosφ=0.4
100
70
50
30
10
0
Operating temperature: +20±2°C
Operating humidity: 65±5%RH
Operating frequency: 20 operations/min
2
4
6
8
10 12
Switching current (A)
Mechanical Durability (for ZC-Q55)
10,000
7,000
5,000
3,000
1,000
700
500
300
100
70
50
30
0 0.1
Operating temperature: +20±2˚C
Operating humidity: 65±5%RH
No load
Operating frequency: 120 operations/min
0.3 0.5 0.7 1
3 5 7 10
OT (mm)
2