English
Language : 

Y92F-40 Datasheet, PDF (2/7 Pages) Omron Electronics LLC – Solid-state Timer
H3M
■ Ratings
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
100/110/120 VAC (50/60 Hz), 200/220/240 VAC (50/60 Hz),
12, 24, 48, 100, 110 VDC (see note 2)
AC: 85% to 110% of rated supply voltage
DC: 80% to 110% of rated supply voltage (see note 3)
AC: Approx. 5 VA/2 W
DC: Approx. 2 W
5 A at 250 VAC, resistive load (cosφ = 1)
Note: 1. Color indicators for the rated voltage are provided on the front of the Timer.
Blue: 100/110/120 VAC
Red: 200/220/240 VAC
None: Other voltages
2. With DC ratings, single-phase full-wave rectified power sources may be used.
3. 90% to 110% for 12-VDC models.
■ Characteristics
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
±1% max. (see note)
±10% max.
0.1 s max.
±1% max. (see note)
±2% max. (see note)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
1,500 VAC, 50/60 Hz for 1 min (between contact and control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Operating: –10°C to 50°C
Storage: –25°C to 65°C
Operating: 35% to 85%
Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
UL (File No. E41515), CSA (File No. LR22310)
Approx. 100 g
Note: For the timer with time range code A, add ±10 ms to the respective characteristics when the time range selector switches are in the x 1 s
(0.05 to 0.5 s) position.