English
Language : 

G6HU-2-DC5 Datasheet, PDF (2/10 Pages) Omron Electronics LLC – Ultra-compact, Ultra-sensitive DPDT Relay
DISCONTINUED
■ Coil Data
Non-latching Type (G6H-2, G6H-2F)
Rated voltage Rated current
Coil
(VDC)
(mA)
resistance
(Ω)
3
46.70
64.30
5
28.10
178
6
23.30
257
9
15.50
579
12
11.70
1,028
24
8.30
2,880
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
0.025
0.022
0.065
0.058
0.11
0.09
0.24
0.20
0.43
0.37
1.20
1.0
48
5.8
8,228
—
—
Pick-up
voltage
75% max.
Dropout
voltage
Maximum
voltage
% of rated voltage
10% min.
200% max. at
23°C
170% max. at
23°C
140% max. at
23°C
Power
consumption
(mW)
Approx. 140
Approx. 200
Approx. 300
Single Coil Latching Type (G6HU-2)
Rated voltage Rated current
Coil
(VDC)
(mA)
resistance
(Ω)
3
33.30
90
5
20
250
6
16.70
360
9
11.10
810
12
8.30
1,440
24
6.25
3,840
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
0.034
0.029
0.11
0.09
0.14
0.12
0.33
0.28
0.60
0.50
1.6
1.3
Set pick-up Reset pick-up Maximum
voltage
voltage
voltage
% of rated voltage
75% max. 75% max.
180% max. at
23°C
Power
consumption
(mW)
Approx. 100
Approx. 150
Dual Coil Latching Type (G6HK-2)
Rated voltage Rated current
Coil
(VDC)
(mA)
resistance
(Ω)
3
66.70
45
5
40
125
6
33.30
180
9
22.20
405
12
16.70
720
24
12.50
1,920
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.014
0.0075
0.042
0.023
0.065
0.035
0.16
0.086
0.3
0.16
0.63
0.33
Set pick-up Reset pick-up Maximum
voltage
voltage
voltage
% of rated voltage
75% max. 75% max.
160% max. at
23°C
130% max. at
23°C
Power
consumption
(mW)
Approx. 200
Approx. 300
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C with a tolerance of ±10%.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. The maximum voltage that can be be applied when using the G6H-2F (at 85°C) is 115% (3 to 12 V) or 105% (24 V) of the rated voltage.
50
Low Signal Relay G6H