G3VM61E1 Datasheet, PDF (2/4 Pages) Omron Electronics LLC – Analog-switching MOS FET Relay for High Analog-switching MOS FET Relay for High 2.5 kVAC between I/O.
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol Rating
Unit
Input LED forward current
IF
50
Repetitive peak LED forward current IFP
1
LED forward current reduction rate Δ IF/°C −0.5
LED reverse voltage
VR
5
Connection temperature
Tj
125
Output Load voltage (AC peak/DC)
VOFF
60
Continuous load Connection A
IO
500
current
Connection B
500
Connection C
1,000
ON current
reduction rate
Connection A
Connection B
Δ ION/°C −0.5
−0.5
Connection C
−10.0
Connection temperature
Tj
125
Dielectric strength between input and
output (See note 1.)
VI-O
2,500
Operating temperature
Ta
−40 to +85
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
Storage temperature
Tstg
−55 to +125 °C
Soldering temperature (10 s)
---
260
°C
Measurement
conditions
100 μs pulses, 100 pps
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
With no icing or
condensation
With no icing or
condensation
10 s
Note:
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Connection Diagram
Connection
A
1 6 Load
2
5
or
AC
DC
34
Connection
B
1 6 Load
25
DC
34
Connection
C
1 6 Load
25
DC
34
■ Electrical Characteristics (Ta = 25°C)
Item
Input LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Output Maximum resistance Connection A
with output ON
Symbol
Mini-
mum
VF
1.0
IR
---
CT
---
IFT
---
RON
---
Connection B
---
Connection C
---
Current leakage when the relay is open ILEAK
Capacity between terminals
A Connection
COFF
Capacity between I/O terminals
CI-O
Insulation resistance
RI-O
Turn-ON time
tON
Turn-OFF time
tOFF
---
---
---
1,000
---
---
Typical
Maxi-
mum
1.15 1.3
---
10
30
---
1.6
3
1
2
0.5
1
0.25 ---
0.001 1.0
130 ---
Unit
V
μA
pF
mA
Ω
Ω
Ω
μA
pF
Measurement
conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 500 mA
IF = 5 mA,
IO = 500 mA
IF = 5 mA,
IO = 500 mA
IF = 5 mA,
IO = 1,000 mA
VOFF = 60 V
V = 0, f = 1MHz
Note:
0.8
---
pF
f = 1 MHz, Vs = 0 V
---
---
MΩ VI-O = 500 VDC,
RoH ≤ 60%
0.8
2.0
ms
IF = 5 mA, RL = 200 Ω,
0.1
0.5
ms
VDD = 20 V (See note 2.)
2. Turn-ON and Turn-OFF
Times
IF 1
2
6 RL
VDD
4
VOUT
IF
VOUT
t ON
10%
90%
t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Load voltage (AC peak/DC)
VDD
Operating LED forward current
IF
Continuous load current (AC peak/DC) IO
Operating temperature
Ta
Minimum
---
5
---
− 20
Typical
---
7.5
---
---
Maximum
48
25
500
65
Unit
V
mA
mA
°C
16