English
Language : 

G3VM-61VY Datasheet, PDF (2/2 Pages) Omron Electronics LLC – Special SOP4-pin package with Dielectric strength AC 3.75 kV
G3VM-61VY
G3VM-61VY
■ Absolute Maximum Ratings (Ta = 25°C)
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Output Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between input and
output (See note 1.)
Operating temperature
Storage temperature
Soldering temperature (10 s)
Symbol
IF
IFP
∆ IF/°C
VR
Tj
VOFF
IO
∆ IO/°C
Tj
VI-O
Rating
50
1
−0.5
5
125
60
70
−0.7
125
3,750
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
Ta
−40 to +85 °C
Tstg
−55 to +125 °C
---
260
°C
Measurement Conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note:
■ Electrical Characteristics (Ta = 25°C)
Item
Input
Output
LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Maximum resistance with output ON
Symbol
VF
IR
CT
IFT
RON
Mini-
mum
1.0
---
---
---
---
Typical Maxi-
mum
1.15
1.3
---
10
30
---
0.6
2
25
50
Current leakage when the relay is
open
Capacity between I/O terminals
Insulation resistance
ILEAK
CI-O
RI-O
---
1
---
0.4
1,000 ---
1000
---
---
Turn-ON time
Turn-OFF time
tON
---
tOFF
---
1
5
0.5
5
Unit
V
µA
pF
mA
Ω
nA
pF
MΩ
ms
ms
Measurement
conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 70 mA
IF = 3 mA,
IO = 70 mA
VOFF = 60 V
f = 1 MHz, Vs = 0 V
VI-O = 500 VDC,
RoH ≤ 60%
IF = 3 mA, RL = 200 Ω,
VDD = 10 V (See note 2.)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
1. The dielectric strength between the
input and output was checked by ap-
plying voltage between all pins as a
group on the LED side and all pins
as a group on the light-receiving
side.
Note:
2. Turn-ON and Turn-OFF
Times
IF 1
2
4 RL
VDD
3
VOUT
IF
VOUT
t ON
10%
90%
t OFF
Item
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Operating temperature
Symbol
VDD
IF
IO
Ta
Minimum
---
---
---
− 20
■ Engineering Data
Load Current vs. Ambient Temperature
G3VM-61VY
100
Typical
---
3
---
---
Maximum
48
25
60
65
Unit
V
mA
mA
°C
■ Safety Precautions
Refer to “Common Precautions” for all G3VM models.
80
60
40
20
0
−20 0
20
40
60
80 100
Ambient temperature (°C)