English
Language : 

G3VM-61DY Datasheet, PDF (2/3 Pages) Omron Electronics LLC – MOS FET Relays
G3VM-61AY/DY
G3VM-61AY/DY
■ Absolute Maximum Ratings (Ta = 25C)
Input
Item
LED forward current
Repetitive peak LED forward
current
LED forward current reduc-
tion rate
LED reverse voltage
Connection temperature
Output Load voltage (AC peak/DC)
Continuous load current (AC
peak/DC)
ON current reduction rate
Pulse ON current
Connection temperature
Dielectric strength between input and
output (See note 1.)
Operating temperature
Storage temperature
Soldering temperature (10 s)
Symbol
IF
IFP
 IF/C
VR
Tj
VOFF
IO
 IO/C
Iop
Tj
VI-O
Ta
Tstg
---
Rating
30
1
Unit
mA
A
0.3
mA/C
5
V
125
C
60
V
500
mA
5.0
1.5
125
5,000
mA/C
A
C
Vrms
40 to +85 C
55 to +125 C
260
C
Measurement Conditions
100 s pulses, 100 pps
Ta  25C
Ta  25C
t = 100 ms, Duty = 1/10
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
■ Electrical Characteristics (Ta = 25C)
Note:
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Item
Input
Output
LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Maximum resistance with output ON
Current leakage when the relay is
open
Capacity between terminals
Capacity between I/O terminals
Insulation resistance
Turn-ON time
Turn-OFF time
Symbol
VF
IR
CT
IFT
RON
Mini-
mum
1.45
---
---
---
---
ILEAK
COFF
CI-O
RI-O
---
---
---
1,000
tON
---
tOFF
---
Typical Maxi-
mum
1.63
1.75
---
10
40
---
0.3
2
0.6
2
---
1.0
130
---
0.8
---
---
---
0.5
1
0.2
1
Unit
V
A
pF
mA

A
pF
pF
M
ms
ms
Measurement
conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 500 mA
IF = 5 mA,
IO = 500 mA
VOFF = 60 V
V = 0, f = 1 MHz
f = 1 MHz, Vs = 0 V
VI-O = 500 VDC,
RoH  60%
IF = 5 mA, RL = 200 
VDD = 20 V (See note 2.)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Note:
2. Turn-ON and Turn-OFF
Times
IF 1
2
4 RL
VDD
3
VOUT
IF
VOUT
t ON
10%
90%
t OFF
Item
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Operating temperature
Symbol
VDD
IF
IO
Ta
Minimum
---
3
---
 20
■ Engineering Data
Load Current vs. Ambient Temperature
G3VM-61AY(DY)
Typical
---
5
---
---
Maximum
48
15
500
65
Unit
V
mA
mA
C
■ Safety Precautions
Refer to “Common Precautions” for all G3VM models.
600
500
400
300
200
100
0
−20 0
20
40
60
80 100
Ambient temperature (°C)
2