English
Language : 

G3VM-61B1 Datasheet, PDF (2/2 Pages) Omron Electronics LLC – MOS FET Relays
G3VM-61B1/E1
G3VM-61B1/E1
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input LED forward current
Repetitive peak LED forward
current
LED forward current reduction
rate
LED reverse voltage
Connection temperature
Output Output dielectric strength
Continuous Connection A
load current Connection B
Connection C
ON current
reduction
rate
Connection A
Connection B
Connection C
Connection temperature
Dielectric strength between input and
output (See note 1.)
Operating temperature
Storage temperature
Soldering temperature (10 s)
Symbol
IF
IFP
D IF/°C
VR
Tj
VOFF
IO
D ION/°C
Tj
VI-O
Ta
Tstg
---
Rating
50
1
-0.5
5
125
60
500
500
1,000
-0.5
-0.5
-10.0
125
2,500
-40 to +85
-55 to +125
260
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement Conditions
100 ms pulses, 100 pps
Ta ³ 25°C
Ta ³ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note:
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Connection Diagram
Connection
A
1 6 Load
2
5
or
AC
DC
34
Connection
B
1 6 Load
25
DC
34
Connection
C
1 6 Load
25
DC
34
■ Electrical Characteristics (Ta = 25°C)
Input
Output
Item
LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Maximum resistance Connection A
with output ON
Symbol
VF
IR
CT
IFT
RON
Mini-
mum
1.0
---
---
---
---
Connection B
---
Connection C
---
Current leakage when the relay is
open
Capacity between I/O terminals
Insulation resistance
Turn-ON time
Turn-OFF time
ILEAK
CI-O
RI-O
tON
tOFF
---
---
1,000
---
---
Typical Maxi-
mum
1.15
1.3
---
10
30
---
1.6
3
1
2
0.5
1
0.25
---
---
1.0
0.8
---
---
---
0.8
2.0
0.1
0.5
Unit
V
mA
pF
mA
W
W
W
mA
pF
MW
ms
ms
Measurement
conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 500 mA
IF = 5 mA,
IO = 500 mA
IF = 5 mA,
IO = 500 mA
IF = 5 mA,
IO = 1,000 mA
VOFF = 60 V
f = 1 MHz, Vs = 0 V
VI-O = 500 VDC,
RoH £ 60%
IF = 5 mA, RL = 200 W,
VDD = 20 V (See note 2.)
Note:
2. Turn-ON and Turn-OFF
Times
IF 1
2
6 RL
VDD
4
VOUT
IF
VOUT
t ON
10%
90%
t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Output dielectric strength
Operating LED forward current
Continuous load current
Operating temperature
Symbol
VDD
IF
IO
Ta
Minimum
---
5
---
- 20
■ Engineering Data
Load Current vs. Ambient Temperature
G3VM-61B1(E1)
Typical
---
7.5
---
---
Maximum
48
25
500
65
Unit
V
mA
mA
°C
■ Safety Precautions
Refer to page 6 for precautions common to all G3VM models.
1,200
Connection C
1,000
800
600
Connection A or connection B
400
200
0
−20 0
20
40
60
80 100
Ambient temperature (°C)
11