English
Language : 

G3VM-601BY Datasheet, PDF (2/6 Pages) Omron Electronics LLC – MOS FET Relays
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input LED forward current
Repetitive peak LED
forward current
LED forward current
reduction rate
LED reverse voltage
Connection temperature
Output Load voltage (AC peak/DC)
Continuous Connection A
load current
Connection B
Connection C
ON current Connection A
reduction rate
Connection B
Connection C
Connection temperature
Dielectric strength between input and
output (See note 1.)
Operating temperature
Storage temperature
Soldering temperature (10 s)
Symbol Rating
IF
50
IFP
1
Unit
mA
A
Δ IF/°C −0.5
mA/°C
VR
5
Tj
125
VOFF
600
IO
100
100
200
Δ ION/°C −1.0
−1.0
−2.0
Tj
125
VI-O
5,000
V
°C
V
mA
mA/°C
°C
Vrms
Ta
−40 to +85 °C
Tstg
−55 to +125 °C
---
260
°C
Measurement conditions
100 μs pulses, 100 pps
Note:
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Connection Diagram
Connection
A
1 6 Load
2
5
or
AC
DC
34
Connection
B
1 6 Load
25
DC
34
Connection
C
1 6 Load
25
DC
34
■ Electrical Characteristics (Ta = 25°C)
Item
Input LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Output Maximum resistance Connection A
with output ON
Symbol
Mini-
mum
VF
1.0
IR
---
CT
---
IFT
---
RON
---
---
Connection B
---
Connection C
---
Current leakage when the relay is open ILEAK
Capacity between terminals
A Connection
COFF
Capacity between I/O terminals
CI-O
Insulation resistance
RI-O
Turn-ON time
tON
Turn-OFF time
tOFF
---
---
---
1,000
---
---
Typical
Maxi-
mum
1.15 1.3
---
10
30
---
1.6
5
25
35
30
45
23
35
12
18
0.0005 1.0
120 ---
0.8
---
---
---
0.2
1.5
0.2
1.0
Unit
V
μA
pF
mA
Ω
Ω
Ω
Ω
μA
pF
pF
MΩ
ms
ms
Measurement
conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 100 mA
IF = 10 mA,
IO = 100 mA, t < 1 s
IF = 10 mA,
IO = 100 mA
IF = 10 mA,
IO = 100 mA
IF = 10 mA,
IO = 200 mA
VOFF = 600 V
V = 0, f = 1MHz
f = 1 MHz, Vs = 0 V
VI-O = 500 VDC,
RoH ≤ 60%
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
Note:
2. Turn-ON and Turn-OFF
Times
IF 1
2
6 RL
VDD
4
VOUT
IF
VOUT
t ON
10%
90%
t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Load voltage (AC peak/DC)
VDD
Operating LED forward current
IF
Continuous load current (AC peak/DC) IO
Operating temperature
Ta
Minimum
---
7.5
---
− 20
Typical
---
15
---
---
Maximum
Unit
480
V
25
mA
100
mA
65
°C
78
MOS FET Relays G3VM-601BY/EY