English
Language : 

G3VM-401B Datasheet, PDF (2/6 Pages) Omron Electronics LLC – MOS FET Relays
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol Rating Unit
Input LED forward current
IF
50
mA
Repetitive peak LED
IFP
1
A
forward current
LED forward current
reduction rate
Δ IF/°C −0.5
mA/°C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
Output Load voltage (AC peak/DC) VOFF 400
V
Continuous Connection A IO
120
mA
load current
Connection B
120
Connection C
240
ON current Connection A Δ ION/°C −1.2
reduction rate
Connection B
−1.2
mA/°C
Connection C
−2.4
Connection temperature
Tj
125
°C
Dielectric strength between input and VI-O
2,500
Vrms
output (See note 1.)
Operating temperature
Ta
−40 to +85 °C
Storage temperature
Tstg
−55 to +125 °C
Soldering temperature (10 s)
---
260
°C
Measurement conditions
100 μs pulses, 100 pps
Note:
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Connection Diagram
Connection
A
1 6 Load
2
5
or
AC
DC
34
Connection
B
1 6 Load
25
DC
34
Connection
C
1 6 Load
25
DC
34
■ Electrical Characteristics (Ta = 25°C)
Item
Input LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Output Maximum resistance Connection A
with output ON
Connection B
Symbol
Mini-
mum
VF
1.0
IR
---
CT
---
IFT
---
RON
---
---
Connection C
---
Current leakage when the relay is open ILEAK
Capacity between terminals
A Connection
COFF
Capacity between I/O terminals
CI-O
Insulation resistance
RI-O
Turn-ON time
tON
Turn-OFF time
tOFF
---
---
---
1,000
---
---
Typical
Maxi-
mum
1.15 1.3
---
10
30
---
1
3
17
35
11
20
6
10
0.0008 1.0
40
---
0.8
---
---
---
0.3
1.0
0.1
1.0
Unit
V
μA
pF
mA
Ω
Ω
Ω
μA
pF
pF
MΩ
ms
ms
Measurement
conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 120 mA
IF = 5 mA,
IO = 120 mA
IF = 5 mA,
IO = 120 mA
IF = 5 mA,
IO = 240 mA
VOFF = 350 V
V = 0, f = 1MHz
f = 1 MHz, Vs = 0 V
VI-O = 500 VDC,
RoH ≤ 60%
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
Note:
2. Turn-ON and Turn-OFF
Times
IF 1
2
6 RL
VDD
4
VOUT
IF
VOUT
t ON
10%
90%
t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Load voltage (AC peak/DC)
VDD
Operating LED forward current
IF
Continuous load current (AC peak/DC) IO
Operating temperature
Ta
Minimum
---
5
---
− 20
Typical
---
7.5
---
---
Maximum
Unit
320
V
25
mA
120
mA
65
°C
70