■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input LED forward current
Repetitive peak LED forward
current
LED forward current reduction
rate
LED reverse voltage
Connection temperature
Output Output dielectric strength
Continuous
load current
Connection A
Connection B
Connection C
ON current
reduction
rate
Connection A
Connection B
Connection C
Connection temperature
Dielectric strength between input and
output (See note 1.)
Operating temperature
Storage temperature
Soldering temperature (10 s)
Symbol
IF
IFP
D IF/°C
VR
Tj
VOFF
IO
D ION/°C
Tj
VI-O
Ta
Tstg
---
Rating
50
1
-0.5
5
125
350
120
120
240
-1.2
-1.2
-2.4
125
1,500
-40 to +85
-55 to +125
260
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement Conditions
100 ms pulses, 100 pps
Ta ³ 25°C
Ta ³ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
■ Electrical Characteristics (Ta = 25°C)
Note:
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Connection Diagram
Connection
A
1 6 Load
2
5
or
AC
DC
34
Connection
B
1 6 Load
25
DC
34
Connection
C
1 6 Load
25
DC
34
Item
Input LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Output Maximum resistance Connection A
with output ON
Connection B
Connection C
Current leakage when the relay is
open
Capacity between I/O terminals
Insulation resistance
Symbol
VF
IR
CT
IFT
RON
ILEAK
CI-O
RI-O
Mini-
mum
1.0
---
---
---
---
---
---
---
---
1,000
Turn-ON time
Turn-OFF time
tON
---
tOFF
---
Typical Maxi-
mum
1.15
1.3
---
10
30
---
1.0
3.0
15
25
8
14
4
---
---
1.0
0.8
---
---
---
---
1.0
---
3.0
Unit
V
mA
pF
mA
W
W
W
mA
pF
MW
ms
ms
Measurement
conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IOFF = 10 mA
IO = 120 mA
IO = 120 mA
IO = 240 mA
VOFF = 350 V, IF = 5 mA
f = 1 MHz, Vs = 0 V
VI-O = 500 VDC,
RoH £ 60%
IF = 5 mA, RL = 200 W,
VDD = 20 V (See note 2.)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Note:
2. Turn-ON and Turn-OFF
Times
IF 1
2
6 RL
VDD
4
VOUT
IF
VOUT
t ON
10%
90%
t OFF
Item
Output dielectric strength
Operating LED forward current
Continuous load current
Operating temperature
Symbol
VDD
IF
IO
Ta
Minimum
---
5
---
- 20
■ Engineering Data
Load Current vs. Ambient Temperature
G3VM-353H
Typical
---
---
---
---
Maximum
280
25
120
65
Unit
V
mA
mA
°C
■ Safety Precautions
Refer to page 6 for precautions common to all G3VM models.
300
250 Connection C
200
150
Connection A or connection B
100
50
0
−20 0
20
40
60
80 100
Ambient temperature (°C)